Installation and connection requirements

The IntenZ CB600 is a versatile product and can be used in many ways. To use this device as intended and 
to be sure that the product is used in a safe way, the following requirements must be met during the setup, 
installation and connection of the device.

Standing installation

The IntenZ CB600 can not directly be installed on a platform without proper mounting gear. Usually, lots of 
light effects have built in rubber feet so they can also be installed on a DJ booth. However, the CB600 has 
large heatsinks on the rear of the unit. If the device would be installed standing, it would fall over. If a 
standing position is desired, the U-bracket must be installed and bolted to the surface it is mounted on. The 
surface must be a solid material like a wooden beam or concrete, in order to keep the CB600 in place. For 
fixed installations this is mostly possible.

Hanging installation

The CB600 can be installed in several ways. Included hanging brackets are included in delivery, which can 
be mounted on top of the unit, next to the coupling hardware. This way, hooks such as G-clamps, trigger 
clamps or half couplers can be installed. 

It is also possible to use the U-shaped bracket, which is mounted on the side of the device. This bracket 
makes precise aiming of this fixture possible, for example when used as a blinder effect in a club or on a 
festival. 

The CB600 can not directly be suspended from a ceiling, wall or beam as its weight is too large. It is however
possible to mount multiple CB600 fixtures to a truss system capable of holding the weight of the CB600 load.

The CB600 are equipped with hardware which makes coupling of multiple CB600 fixtures possible, thus 
creating a wall of LED-pixels. For this application, the included tool is used. The panels are positioned next to
each other and with the tool, the hook from one panel attaches to the panel hooks next to it. Please pay 
close attention to the positioning of each attached panel, as the devices must all be positioned in the same 
direction to achieve  optimal effects. 

Please note that every suspended installed CB600 needs to be secured to its main structure with safety 
cables. The provided safety eyebolts of the CB600 can be used for this and are positioned in the top corners 
of the rear panel. 

When the units are used in a matrix setup, every fixture needs to be secured separately to ensure safety. If 
any of the primary mounting hardware fails, the unit can not fall. Each unit should not be able to fall more 
than 30 cm and the used safety cable must be able to hold at least 10x the weight of the load it protects. 

No more than 4 units may be installed vertically below each other. When doing so, the smaller U-shaped 
brackets must be installed on top of the upper unit. Trigger couplers or likewise clamps, capable of holding at
least 10x the weight of the unit, can be used to mount the matrix to a truss system. 

The fixtures can be coupled as shown on the next page.

All information and illustrations shown in this user manual are subject to change without further notice.

User manual version: 1.0

Creation date + author initials: 13-05-2015 RV Revision date + author initials: 

Содержание 9000-0021-6272

Страница 1: ...Matrix panel User manual All information and illustrations shown in this user manual are subject to change without further notice User manual version 1 0 Creation date author initials 13 05 2015 RV R...

Страница 2: ...bles lying around Do not open the device and do not modify any hardware or software Do not insert objects into air vents of this device Do not connect this device to a dimmer pack Do not switch the sy...

Страница 3: ...ct with a wrong type of power supply may cause permanent damage to the device Avoid shocks and collision during use and transport Do not transport the device while in use Avoid brute force during the...

Страница 4: ...the EU Do not dispose of this product together with regular household trash Contact your local government for more information about proper disposal and recycling of electronic products in your region...

Страница 5: ...broken or has visible damage do not use it If the unit is not going to be used for a longer period of time disconnect it from the power supply and store it in a dust free environment Always check the...

Страница 6: ...compartment 9 Power on off 10 DMX input 3p 11 DMX output 3p 12 DMX input 5p 13 DMX output 5p 14 Matrix coupling hardware All information and illustrations shown in this user manual are subject to chan...

Страница 7: ...not in use DISP Display inversion Flips display for easier reading TEST Test mode Tests all LEDs and colours TEMP Temperature Temperature display Celsius HOUR Working hours Amount of hours device has...

Страница 8: ...e time When turned off the display will turn off when not used for around 1 minute DISP Display flip function When you invert the display status the status of the buttons will also change From the cor...

Страница 9: ...d light shows in the automatic or sound controlled mode The first fixture in the chain must be set in the Auto or Music mode and the other fixtures must be set to Slave so they will mimic the behaviou...

Страница 10: ...CB600 can be switched between various channel modes For simple applications where a minimum amount of control is required the 1CH mode is perfect Users who wish to have ultimate control over all pixel...

Страница 11: ...no function 008 255 colour selection CH5 Colour macro head 5 000 007 no function 008 255 colour selection CH6 Colour macro head 6 000 007 no function 008 255 colour selection CH7 Colour macro head 7 0...

Страница 12: ...255 colour selection CH11 Colour macro head 11 000 007 no function 008 255 colour selection CH12 Colour macro head 12 000 007 no function 008 255 colour selection CH13 Colour macro head 13 000 007 no...

Страница 13: ...255 0 100 CH49 Master dimmer 0 100 000 255 0 100 CH50 Strobe function 000 007 No function 008 015 Full on 016 255 Strobe slow fast 51CH mode CH Function Values CH 1 4 7 10 13 16 19 22 25 28 31 34 37 4...

Страница 14: ...however possible to mount multiple CB600 fixtures to a truss system capable of holding the weight of the CB600 load The CB600 are equipped with hardware which makes coupling of multiple CB600 fixture...

Страница 15: ...n CB600 This also means that one matrix consisting of 16 CB600 fixtures can run on a single power cable Please note that a clean 16A power group is also required in order for the matrix to work proper...

Страница 16: ...lly the locking part has to be pressed and held to unlock the mechanism When doing this the connector can be removed from its socket Fans and cooling The IntenZ CB600 is a modern product and features...

Страница 17: ...response or DMX activity signal LEDs active Check your DMX cables for possible connector breaks and replace them if necessary Wrong working mode Switch the working mode of the device to DMX mode The f...

Страница 18: ...alue is set change the channel mode to a different setting and try again I cannot switch working modes Fixture set to slave mode Enter the menu and adjust the Master slave function to Master if it is...

Страница 19: ...in XLR DMX input output on off switch LED display with menu buttons for setting adjustments Technical details 16x 30W RGB COB LED chip beam angle 31 degrees each LED 54 degrees full on power connectio...

Отзывы: