Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this 

product must be performed by a qualified electrician. This product must be installed in accordance 

with the applicable installation code by a person familiar with the construction and operation of the 

product and hazards involved. 

Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting 

any maintenance. Disconnect power at fuse or circuit breaker.

Risk of Fire- Minimum 90°C supply conductors.

Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.

Risk of Personal Injury- Due to sharp edges, handle with care.

Failure to comply with these instructions may result in death, serious bodily injury and property 

damage.

WARNING

DISCLAIMER OF LIABILITY: 

Cooper Lighting Solutions

 assumes no liability for damages or losses of any kind 

that may arise from the improper, careless, or negligent installation, handling or use of this product. 

 

IMPORTANT:

 Read carefully before installing fixture. Retain for future reference.  

NOTICE:

 Green ground screw provided in proper location. Do not relocate.

NOTICE:

 Fixture may become damaged and/or unstable if not installed properly.

Note:

 Specifications and dimensions subject to change without notice.

ATTENTION Receiving Department:

 Note actual fixture description of any shortage or noticeable damage on 

delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be 
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

Installation Instructions – 

Define S122-125 IP 

Wiring Table

Power Supply (Input)

When Applicable

Black (BK) - Hot

White (WH) - Neutral

Green (GN) - Ground

Purple (PU) - 0-10V (+)

Gray (GR) - 0-10V (-)

Emergency Hot – Black/Red
Emergency Neutral – White/Red
Second Circuit Hot – Black/Orange
Second Circuit Neutral – White/Orange
Second Circuit Dimming Positive – Orange
Second Circuit Dimming Negative – Yellow
Battery/Emergency Unswitched Hot – Blue

Maximum Sink/Source current per fixture is 6mA

Summary of Contents for Neo-Ray Define S122 IP

Page 1: ... the improper careless or negligent installation handling or use of this product IMPORTANT Read carefully before installing fixture Retain for future reference NOTICE Green ground screw provided in proper location Do not relocate NOTICE Fixture may become damaged and or unstable if not installed properly Note Specifications and dimensions subject to change without notice ATTENTION Receiving Depart...

Page 2: ...plate by slidinng the lens out of the way andremoving two 8 32 screws Pull aircraft cable through griplocks and adjust to desired height Make sure to level the fixture correctly applies to individuals or first piece in row Parts List Fixture Access Plate Push In Connectors Cast Joiner Torx Screws Additional 8 32 Phillips Screws Phillips Screw Driver Bit 6L T15Torx Screwdriver Bit Rubber Mallet T 1...

Page 3: ...n the row using the griplock and pre installed aircraft cable Temporarily support the other end Ensure the alignment pins and cast joiners are seated correctly in the adjoining fixture FOR CONTINUOUS ROWS ONLY Hang far end of the next fixture in the row using the griplock and pre installed aircraft cable Temporarily rest adjoining fixture on the first and join dimming and power wires using the pro...

Page 4: ...VINGTHE FIXTURES UNFASTENED BY MECHANICAL MEANS Fixture can be leveled via grip lock on opposite end of fixture Once fixtures are flush to one another and level install torx head screw through cast joiners to snug fixtures together DO NOT OVERTIGHTEN Torx screw will pull fixtures together tightly without too much force Replace all access plates and move lenses back to proper positions The fixture ...

Page 5: ...device must accept any interference received including interference that may cause undesired operation Note The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance Such modifications could void the user s authority to operate the equipment Note The equipment has been tested and found to comply with the limits for a Class B digi...

Reviews: