4
CONNECTING LINE SUPPLY
Connect power line cables to the terminals
L1/R, L2/S, L3/T and N.
CONNECTING MOTOR POWER
1.
Connect motor power inputs to U, V, W terminals in
controller box.
2.
Use the given shielded motor cable for this.
3.
Connect shielding of the cable to the earth bar in the
controller.
CONNECTING BRAKING RESISTOR
1.
Fix the braking resistor onto the wall or control panel
box.
2.
Do not put the resistor into the control panel box.
3.
Be aware that it will be hot and will emit heat to the
surroundings during lift operation. Do not touch it during
operation.
4.
Connect the cables of the braking resistor to the
terminals P+, DB in XK-BRK2 group in control box.
5.
Connect the shielding of the cable to the earth bar inside
the control panel.
6.
Do not run the motor without connecting the
appropriate braking resistor. Otherwise the device may
be damaged.
CONNECTING RECALL COMMAND BOX
Connect recall command box to the controller on HT-KL terminal
board by plugging XK-PREV1 and XK-PREV2 sockets.