CAR LIMIT SWITCH

 

 

Mount mechanical limit switch with roller by using supplied 
metal bracket onto the cartop. 

 

Connect its cable to X-KLSK socket to PWH board in 
inspection box. 

 

Move the car to downwards with inspection or recall 
command to the position where the car is just below the 
shaft limit. 

 

Place and fix the lower shaft limit cam there. 

 

Move the car to upwards with inspection or recall command 
to the position where the car is just above the shaft limit. 

 

Place and fix the upper car limit cam there.

 

 

INSTALLATION OF FLOOR SELECTOR AND ADJUSTING FLOORS 

 

 

After selecting the floor selector system that you are going to 
use in parameter A05 go to the document in Appendix-1 
about floor selector installation. 
 

 

Installing shaft switches, teaching floor levels and fine floor 
adjustments is explained in this manual. 

 

 

CLEARING PERMANENT ERRORS 

 

Some critical errors, mainly UCM (unintended car motion) 
error block the lift and do not allow further operation. 

 

These errors are even not cleared when the system is 
switched off. 

 

The only way to get rid of them is using a special error 
clearing section. 

 

Go to SERVICES icon and then select line R01-UCM-CLEAR 
ERROR 
in services menu. 

 

 

TESTING SAFETY FUNCTIONS 

 

There are a number of test routines implemented in 
software. 

 

They can be started in SERVICES menu. 

 

SHAFT LIMIT TEST 
The performance of the shaft limit switches can be tested by 
using this test. See section 10.2 in device user manual for 
detailed explanation of this test. 

 

MANUAL UCM TEST 
This test has been implemented to simulate an unintended 
car motion situation and see the response of the system. See 
section 7.4 in device user manual for detailed explanation of 
this test. 

 

 

Содержание AE-MAESTRO

Страница 1: ...ectric Package of Gearless Lift Machines Document Name AE MAESTRO Lift Controller Installation Manual for Electric Package of Gearless Lift Machines Document Code AEM INSEN GL Document Version 1 08d S...

Страница 2: ...able groups with their related information written on them To avoid any wrong connection check the labels before connecting any socket or terminal CAUTION This document is a quick installation documen...

Страница 3: ...Cartop Emergency Lighting 5 Cartop Box 6 Audible and Flashing Device 7 Pit Control Unit 8 Pit Command Box 9 Pit Inspection Reset Switch 10 Machine Side Stop Button 11 Shaft Limit Switch 12 ML1 ML2 Ma...

Страница 4: ...ch Used to stop the lift in machine room Used under the car Connected to Controller Used at the base landing floor Magnetic Switches Flex Holder Strip and Round Magnets Shaft Limit Switch Used on the...

Страница 5: ...the resistor into the control panel box 3 Be aware that it will be hot and will emit heat to the surroundings during lift operation Do not touch it during operation 4 Connect the cables of the braking...

Страница 6: ...in the figure to the related controller terminals 5 Note that the brake monitoring contacts are normally closed NC 6 Connect machine stop to 110 and 110A terminals EN81 20 CONTROLLER OUTPUT TERMINALS...

Страница 7: ...ct the inspection box in machine room This is necessary to have the safety contacts closed in order to run motor for autotuning 1 Take 24 wire flex cable and connect its terminals labelled with XK FLX...

Страница 8: ...d and CON socket of the second ALYA car panel in the cabin Set door type to B from ALYA car panel dip switch 2 For other COP Series a Connect cable labelled CON A between CON A socket in PWL board and...

Страница 9: ...ING OPERATING PANEL in Appendix 6 Fix LOPs to the walls at the landings regarding to the instructions in AP 03 7 Connect XK CB socket to the controller 8 Connect all landing panels to the cable of XK...

Страница 10: ...t pit devices to the terminals of the KDM box as shown on the diagram in the project schemas Place KRR switch at the landing onto door frame or onto a wall near it It must be located outside of the sh...

Страница 11: ...Otherwise connect encoder to ICA board regarding the colours given in the data sheet of the encoder used 4 Encoder cables should be connected to ICA board as shown the diagrams below 5 Please check d...

Страница 12: ...uld be used to adjust parameters and carry on the services implemented in the device software It must not be present during operation of the lift Hand terminal can be used as plugged onto the device a...

Страница 13: ...lect Group A by using up and down arrows and press ENT when Group A is highlighted You can select other parameter groups similarly Then select A01 NUMBER OF FLOORS in order to change number of floors...

Страница 14: ...into the slot in the hand terminal Place hand terminal onto the device Update operation cannot be performed via CAN Bus Select Data Software icon There are two processors inside the device Therefore...

Страница 15: ...itches magnets etc Installation Mode is only in inspection mode active Its value will be switched to 0 as soon as the system is switched to the normal mode Once setup application has been started you...

Страница 16: ...nary Tuning In this method tuning process is carried out without any rotation of motor This method should be selected if the ropes have already been hanged onto the pulley Otherwise rotating tuning is...

Страница 17: ...ge 2 So tuning operation has been started Continue pressing onto RUN button on recall command box IN OPERATION In rotating tuning 1 If the motor rotates more than one tour then terminate operation by...

Страница 18: ...motor and the device output should be checked ENABLE ERROR This error arises if the safety line is cut by any reason during the operation Releasing RUN button may cause this error TUNING ERROR Any rot...

Страница 19: ...cable groups 1 XL DS carries door control signals from PWL The signals are KA output is Door Open Command KK output is Door Close Command KO is the common terminal of KA and KK R3 is the Slow Close C...

Страница 20: ...systems with two automatic doors landing door contacts of side B are bridged In systems with semiautomatic doors landing door contacts are bridged Position 2 125 130 are bridged This means In systems...

Страница 21: ...es teaching floor levels and fine floor adjustments is explained in this manual CLEARING PERMANENT ERRORS Some critical errors mainly UCM unintended car motion error block the lift and do not allow fu...

Страница 22: ...method can be used only if the car has a weight measuring device installed SETUP OF ANTI ROLLBACK SYSTEM without load sensor To activate Anti Rollback function set S19 STARTING MODE in SPEED PARAMETER...

Отзывы: