16
TUNING IN OPERATION
Turn on INSPECTION switch on recall command box
to INSP position.
The system must stay in inspection mode and safety
line must be closed along the operation to execute
tuning process.
To start tuning operation, select R04-TUNING under
SERVICES icon.
The car must not be staying at bottom or at top
floor. Move it anywhere not close to the ends of the
shaft.
Operation Stage 1
Press the blue RUN button on the recall command
box and hold it pressed until the end of the tuning
process.
Press UP arrow button on the hand terminal to start
the operation.
Operation Stage 2
So, tuning operation has been started.
Continue pressing onto RUN button on recall
command box.
IN OPERATION
In rotating tuning…
1.
If the motor rotates more than one tour, then
terminate operation by releasing RUN button.
2.
In rotating tuning the motor rotates smoothly until
the nearest pole position.
3.
If it is currently staying just in its pole position, then
it firstly rotates for some degrees to get away from
this position and rotates again to find the pole
position.
4.
If there is no rotation the system will terminate the
operation by giving an error message.
5.
Increase the value of the parameter C20-TUNING
CURRENT and repeat the tuning operation once
more.
6.
If the operation fails again, then increase C20 step
by step until the tuning operation will complete
successfully.