5
CONNECTING BRAKE, THERMISTOR AND MACHINE SIDE STOP
1.
Motor brakes, thermistor and stop are placed in XK-
BRK2 terminal group in controller box.
2.
Connect motor thermistor to T1 and T2 terminals in
controller box.
3.
If there is no thermistor in motor then bridge T1 and
T2 terminals in controller.
4.
Connect brake coils and brake contacts as shown in
the figure to the related controller terminals.
5.
Note that the brake monitoring contacts are
normally closed (NC).
6.
Connect machine stop to 110 and 110A terminals
(EN81-20).
CONTROLLER OUTPUT TERMINALS AND SOCKETS
The system is prewired. Therefore, there are very few direct cable connections to the controller. The
connections are mostly done by plugging sockets or connecting external devices to the labelled dummy
terminal. The drawing below shows the output terminals of the controller. The sockets have been
arranged in groups for specific tasks.