37
Table 3 Charge Mode Specifications
Utility Charging Mode
INVERTER MODEL
5KW
Charging Current (UPS)
@ Nominal Input Voltage
80A
Bulk Charging
Voltage
Flooded
Battery
58.4
AGM / Gel
Battery
56.4
Floating Charging Voltage
54Vdc
Overcharge Protection
64Vdc
Charging Algorithm
3-Step
Charging Curve
Time
Battery Voltage, per cell
Charging Current, %
100%
50%
Bulk
(Constant Current)
Absorption
(Constant Voltage)
Maintenance
(Floating)
Current
Voltage
T1
T1 = 10* T0, minimum 10mins, maximum 8hrs
T0
2.43Vdc (2.35Vdc)
2.25Vdc
Solar Input
INVERTER MODEL
5KW
Rated Power
5000W
Max. PV Array Open Circuit Voltage
450Vdc
PV Array MPPT Voltage Range
120Vdc~430Vdc
Max. Input Current
18A
Table 4 General Specifications
INVERTER MODEL
5 KW
Safety Certification
CE
Operating Temperature Range
-10°C to 50°C
Storage temperature
-15°C~ 60°C
Humidity
5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm
140 x 295 x 468
Net Weight, kg
12