17
default setting: 54V
10% (default)
If “WECO battery” is selected in
program 5, this parameter value
will be displayed in percentage and
value setting is based on battery
capacity percentage. The setting
range is from 10% to 100%.
Increment of each click is 5%.
16
Charger source priority:
To configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only
when solar energy is not available.
Utility first
Utility will charge battery as first
priority. Solar energy will charge
battery only when utility power is
not available.
Solar and Utility
(Default)
Solar energy and utility will charge
battery at the same time.
Only Solar
Solar energy will be the only
charger source no matter utility is
available or not.
If this inverter/charger is working in Battery mode or Power saving
mode, only solar energy can charge battery. Solar energy will
charge battery if it's available and sufficient.