AXIS P5635-E Mk II PTZ Dome Network Camera
Specifications
Function
Pin
Notes
Specifications
AC/DC Power
input
9, 10
The input is polarity independent. Use a Safety Extra Low
Voltage (SELV) compliant limited power source (LPS) with
either a rated output power limited to ≤100 W or a rated
output current limited to ≤5 A.
24 V AC/DC
Digital input – Connect to pin 8 to activate, or leave
floating (unconnected) to deactivate.
0 to max 30 V DC
Configurable
(Input or Output)
3 – I/O 1
5 – I/O 2
6 – I/O 3
7 – I/O 4
Digital output – Connected to pin 8 when activated,
floating (unconnected) when deactivated. If used with an
inductive load, e.g. a relay, a diode must be connected
in parallel with the load, for protection against voltage
transients.
0 to max 30 V DC, open drain,
100 mA
DC Output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA
GND
8
Ground for audio and I/O
Audio Line Out
4
Can be connected to a public address (PA) system or an
active speaker with a built-in amplifier
Audio In
1
Balanced or unbalanced input for a mono microphone
or line signal