UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 68-81
Figure 37. Example Configuration. LIN Signal #5
Now, configure
LIN Unconditional Frame #1
. Set
LIN Frame Kind
to
Publish
,
Frame ID
to
0x23
,
Size
to
5 bytes
. Add all previously configured LIN signals to the frame using
(Signal
#1…10
Number, Signal
#1…10 Offset)
configuration parameter pairs.