UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 21-81
3.3.2 LIN Signal
LIN Signal
function blocks are used to specify input and output signals on the LIN bus. There
are
130
LIN Signal
function blocks available to the user. Each
LIN Signal
function block has
one signal input and one signal output for interfacing with other function blocks.
Figure 7. LIN Signal Function Block
Configuration parameters of the
LIN Signal
function block are presented below:
Table 14. LIN Signal Function Block Configuration Parameters
Name
Default
Value
Range
Units
Description
LIN Signal Type
Undefined
{Undefined, Scalar, Byte
Array}
–
Type of the LIN signal.
Input Signal
Source
Not
Connected
Any signal output of any
function block or “Not
Connected”
–
Input signal source if LIN
signal is output (data is
sent on the LIN bus).
Output Signal
Autoreset Time
1000
[1…10000]
ms
Autoreset time if LIN
signal is input (data is
received from the LIN
bus). If 0
– Autoreset is
disabled.
Size
1
[1…64]
bit
Signal size.
Encoding Type
Undefined
{Undefined, Logical
Value, Physical Value,
BCD Value, ASCII Value}
–
Type of the LIN signal
content.
Min Value
0
[0…0xFFFFFFFF]
–
Min value of the signal
code when the Encoding
Type is “Logical Value” or
“Physical Value”.
Max Value
1
[0…0xFFFFFFFF]
–
Max value of the signal
code when the Encoding
Type is “Logical Value” or
“Physical Value”.
Scale
1
Any value
Signal
Units/bit
Signal scale when the
Encoding Type is
“Physical Value”.
Offset
0
Any value
Signal
Units
Signal offset when the
Encoding Type is
“Physical Value”.
Init Value Scalar
0
[0…0xFFFF]
–
Initial signal value when
LIN Signal Type is Scalar.
LIN
Signal
#1…130
Signal
Output
Signal Input