UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 51-81
Name
Default
Value
Range
Units
Description
Signal 1 Data Index
in Array (LSB)
1
[1…8]
–
Byte position of the 1-st
CAN output signal.
Signal 1 Bit Index
in Byte (LSB)
1
[1…8]
–
Bit position of the 1-st
CAN output signal.
Signal 1 Data
Resolution
1
Any value
Signal
Units /
bit
Resolution of the 1-st
CAN continuous output
signal.
Signal 1 Data
Offset
0
Any value
Signal
Units
Offset of the 1-st CAN
continuous output signal.
Signal 2 Data Type
Undefined
{Undefined, Discrete,
Continuous}
–
Type of the 2-nd CAN
output signal.
Signal 2 Data
Source
Control Not
Used
Any signal output of any
function block or
“Control Not Used”
–
Input signal source of the
2-nd CAN output signal.
Signal 2 Data
Number
0
Depends on the data
source chosen
–
Input signal number of the
2-nd CAN output signal
Signal 2 Data Size
1
[1…32]
bit
Size of the 2-nd CAN
output signal.
Signal 2 Data Index
in Array (LSB)
1
[1…8]
–
Byte position of the 2-nd
CAN output signal.
Signal 2 Bit Index
in Byte (LSB)
1
[1…8]
–
Bit position of the 2-nd
CAN output signal.
Signal 2 Data
Resolution
1
Any value
Signal
Units /
bit
Resolution of the 2-nd
CAN continuous output
signal.
Signal 2 Data
Offset
0
Any value
Signal
Units
Offset of the 2-nd CAN
continuous output signal.
…
…
…
…
…
Signal 5 Data Type
Undefined
{Undefined, Discrete,
Continuous}
–
Type of the 5-th CAN
output signal.
Signal 5 Data
Source
Control Not
Used
Any signal output of any
function block or
“Control Not Used”
–
Input signal source of the
5-th CAN output signal.
Signal 5 Data
Number
0
Depends on the data
source chosen
–
Input signal number of the
5-th CAN output signal
Signal 5 Data Size
1
[1…32]
bit
Size of the 5-th CAN
output signal.
Signal 5 Data Index
in Array (LSB)
1
[1…8]
–
Byte position of the 5-th
CAN output signal.
Signal 5 Bit Index
in Byte (LSB)
1
[1…8]
–
Bit position of the 5-th
CAN output signal.
Signal 5 Data
Resolution
1
Any value
Signal
Units /
bit
Resolution of the 5-th
CAN continuous output
signal.
Signal 5 Data
Offset
0
Any value
Signal
Units
Offset of the 5-th CAN
continuous output signal.
1
X is defined by the Block Number, ex. X=1 for CAN Transmit 1
2
Proprietary A PGN (61184) is excluded. It is taken by Axiomatic Simple Proprietary Protocol and