UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 13-81
3.2 PWM Output
Table 4. PWM Output Function Block Configuration Parameters
Name
Default Value
Range
Description
Output Type
1, Digital PWM
Drop List
See Table 5.
Output at Minimum
Command
0.00
Depends on
Output
Type
Digital PWM:
Digital Mixed PWM and Frequency:
[0…100] %DC
Digital Frequency: [0.1…20000] Hz
Digital ON/OFF: [0…1]
Output at Maximum
Command
100.00
Depends on
Output
Type
Ramp Up (Min to
Max)
0ms
0 to 10,000
Unit in milliseconds
Ramp Down (Max to
Min)
0ms
0 to 10,000
Unit in milliseconds
Fixed Frequency/Duty
Cycle
500Hz
Depends on
Output
Type
Default values depend on output
type.
Digital Control
Response
0, Normal Logic
Drop List
Only configurable when output type
is set to Digital ON/OFF. See Table
6.
Digital Blink Rate
500ms
100 to
5,000
Only configurable when control
response is set to Blink Logic.
Digital Type VPS
Range
0, 0V to 6V
Drop List
0 = 0V to 6V
1 = 0V to 13V
Control Source
1, CAN Receive
Messages
Drop List
See Table 8.
Control Number
1, CAN Receive
Messages #1
Per Source
See Table 8.
Control Response
1, Off Below Control
Minimum
Drop List
See Table 9.
Enable Source
0, Control Not Used
Drop List
See Table 8.
Enable Number
N/A
Per Source
See Table 8.
Enable Response
N/A
Drop List
See Table 10.
Override Source
0, Control Not Used
Drop List
See Table 8.
Override Number
N/A
Per Source
See Table 8.
Override Response
N/A
Drop List
See Table 11.
Output at Override
Command
1V
Depends on
Output
Type
Same as minimum and maximum
command
Fault Response
1, Output Fault
Mode Value
Drop List
See Table 12.
Output at Fault
Command
0V
Depends on
Output
Type
Same as minimum and maximum
command
Fault Detection is
Enabled
True
False or
True
See Section 3.2.4 and 3.9
Event Generates a
DTC in DM1
False
False or
True
See Section 3.2.4 and 3.9
Event Cleared Only
by DM11
False
False or
True
See Section 3.2.4 and 3.9