UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 60-81
The user can view and, when necessary, change configuration parameters by double-clicking
on the appropriate setpoint name. A pop-up dialog window will appear, see figure below.
Figure 30. Changing a Configuration Parameter in EA
If the user changes the configuration parameter, the new value will be stored in a non-volatile
memory and used immediately by the converter.
The converter will perform an internal reset of all function blocks after each change of the
configuration parameters. If the new configuration parameter affects the CAN network
identification, the converter will reclaim its network address with a new network identification
message.
4.3 Setpoint File
The EA can store all converter configuration parameters in one setpoint file and then flash
them into the converter in one operation.
The setpoint file is created and stored on disk using a command
Save Setpoint File
from the
EA menu or toolbar. The user then can open the setpoint file, view or print it, and also flash
the setpoint file into the converter, see figure below.