![AXIOMATIC AXTC4CO Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/axiomatic/axtc4co/axtc4co_user-manual_3037100037.webp)
UMAXTC20CO V1.1.1 Preliminary Documentation – May be Subject to Change 37-59
Entry Description
Sub-Index 0h
Description Largest
sub-index supported
Access RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (X = 1 to 4)
Description Thermocouple X Operating Mode
Access RW
PDO Mapping
No
Value Range
0 or 1
Default Value
1 (Normal Operation)
3.3.4.
Object 6114h: ADC Sample Rate
This read-only object is available to reflect the scan rate of each channel. It is fixed at 200ms. The
unit for this object is microseconds.
Object Description
Index 6114h
Name
ADC Sample Rate
Object Type
ARRAY
Data Type
UNSIGNED32
Entry Description
Sub-Index 0h
Description Largest
sub-index supported
Access RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (X = 1 to 4)
Description
Thermocouple X Sample Rate
Access RO
PDO Mapping
No
Value Range
N/A
Default Value
200000 (200ms)