- 21 -
CONFIGURING THE VERIFIER
All of the primary configuration of the verifier is done through the “Set-
up” icon
Press this to enter the “Set-Up” dialogue.
There are a range of tabs to cover the different groups of parameters.
Here is shown the “
General
” group
Standards: Click on “ISO” if you want only the numeric ISO result to be
shown – or click on “ANSI” if you would prefer to be shown both results.
Units:- The “default” is to track the Windows settings for metric or
imperial measurements – alternatively you can set this as required.
Pass Grade:- If you are working on barcodes within the retail supply chain
then the “Apply GS1 General Specifications” should always remain ticked
on. The user can select the pass/fail grade for other barcode types as
specified either by an Industry Application Specification or by their
customer.
Magnification factor:- This remains for continued support for Axicon
customers who have the earlier model 5000 verifiers. For all others the
settings in this field have no effect.
The next tab is “
Check Characters
”
Most barcode symbologies (types) have
mandatory check digits and these will
be automatically validated as to their