background image

Содержание Unitel DI-623-21L

Страница 1: ...I In ns st ta al ll la at ti io on n a an nd d u us se er r m ma an nu ua al l U UN NI IT TE EL L DI 623 21L ...

Страница 2: ......

Страница 3: ...talk to the visitor If you want to open the door for the visitor press the five button and hang up 15 sec before you are disconnected you get a warning signal If you want to extend the connection with _____sec Press the 2 button At the entrance you can always break the call by using the button The possibility to open the door with the 5 button is enabled during the following times If you don t wan...

Страница 4: ... 623 21 SWITCH BOARD 4 6 8 0 2 1 3 5 7 9 The green LED on the front panel indicates door open and the yellow indicates key pressed The red LED lights constant when you are connected to the switch board and flashes when the line is occupied by another telephone connected to the same line When red LED is flashing also see Point 10 side 8 To open the door you enter a valid code To call on a person yo...

Страница 5: ...as to be initialised with a special code This code pre sets printer parameters clears the memory including the password sets the opening time to 7 sec and sets the time of call to 60 sec The code is 199200 INITIALISATION AND MEMORY RESET Open the door unit Press and release RST button on the circuit board and wait for four short beep Enter 199200 Press 6 short signals are heard Note The memory is ...

Страница 6: ...time control 1 Code disabledif PL2 15 PL2 16 is open 2 Code disabledif PL2 15 PL2 16 is closed Programming is done in the following way Enter your password You will hear a beep every second Press and the address for the fist code number which is 101 and you hear a double beep Enter a code number with optional number of digits max 14 Press and you hear a double beep Enter a function 1 2 and you hea...

Страница 7: ...f your password is 123456 and an 1234 is a door code the door will open on 1234 and the code lock will enter programming mode after 6 digits 4 CANCEL CODES TELEPHONE NUMBERS If you want to cancel number or a code e g code 1 do the following Enter your password Press 101 The code is erased and the code lock returns to programming mode Press The unit returns to working mode 5 PROGRAMMING OF TIME OF ...

Страница 8: ...th 5 function is 0 Always activated 1 Disabled if PL2 15 PL2 16 is open 2 Disabled if PL2 15 PL2 16 is closed 3 Always disabled To prevent a person to call a number outside the company you can limit the length of the number that can be dialled from the keypad Numbers that are programmed in the memory are not influenced The limit is set by programming a second digit after 39 This digit can be betwe...

Страница 9: ... and functions are printed out Example of printout The printout shows that this is a DI 623 21L software version 1 0 with the unit ID 01 The second line indicates that the open with five function is disabled and that the length of the calling number is 4 digits Line 3 shows that the opening time is 7 sec and line 4 that the time of call is 60 sec Line 5 shows that if you if you close PL1 6 and PL2...

Страница 10: ...ed in some cases e g if the power on the line is to low below app 20V red LED flashes or in the case the PABX detects the break as an impulse 0 a dead or fault connection Following settings is possible 0 Disabled beep and Enabledline test 1 Enabledbeep and Enabledline test default at 199200 2 Disabled beep and Disabled line test 3 Enabledbeep and Disabled line test For setting Disconnect the power...

Страница 11: ...s used Enter Delete PRINTOUT OPENING TIME TIME OF CALL UNIT ID SPECIAL FUNCTION RST button RST button Password Password Password Password Password Password Password 199200 6 digit code 101 199 39 1 14 digits Function Disable function Disable five 101 199 82 51 sec 53 min 52 sec 54 min 44 01 99 01 99 01 99 0 9 Limit number l ...

Страница 12: ...9 20 21 22 23 24 Normally in position A Disable Intercom answering _ 12V 24V Electric lock Telephone line Connection of DI 608 Speaker volume K1 TxD GND RxD Busy Tamper A ONOFF Power supply Connector for prox reader See manuals for each control unit B K4 Voltage jumper ...

Страница 13: ...I 623 08 you have to make an hardware addressing This is done with the jumpers A0 A2 As delivered the jumper A0 A2 is set as below Default This corresponds to addresses 109 to 116 in DI 623 21L You can see a list of addresses and jumpers in the diagram below To change an address you just put A0 A2 so that the right address is achieved 1 PL1 PL2 TO K1 ON ADI 623 XX T0 K1 ON NEXT ADI 623 08 ADI 623 ...

Страница 14: ...AXCALL 12 LIST OF NUMBERS CODES IN DI 623 21L ...

Страница 15: ......

Страница 16: ...Installed by Telephone ...

Отзывы: