DETAIL OF HYBRID REMOTER FOR MACROTEL X1
| DETAIL OF HYBRID REMOTER FOR MACROTEL X1
41
14.5.5 Macrotel X1 and Macrotel X2 Program Settings section
The
Program Settings
section shows all the functions of the Hybrid Remoter Control Software and of the Macrotel X1
and Macrotel X2 devices.
Visualisation & Program Features:
The “Show peak meter” checkbox offers the possibility to see the peak meter on
the levels section of the two Hybrids.
Setup Password:
This field is used to enter an alphanumeric Password of
maximum 8 digits, which is required to access the device Setup section.
Enter the password and click Return. This password must be entered in the
User Authentication box to access the Setup section. If you forget the
password the device must be returned to the manufacturer in order to be
used again
. There are no backdoors and Axel Technology’s Technical
Assistance Service is not authorised to instruct others to tamper with the
device.
Information:
This panel provides a summary of the Macrotel X1 or
Macrotel X2 model in use, the name of the device, the firmware
version installed on the DSP of the device and the univocal firmware
code assigned to each single device. The Copy Firmware code to
Clipboard key is used to save the Firmware code in the notebook, so
that this alphanumeric code can be sent to Axel technology to
execute Upgrades or improve the product.
The
Connection Information
box shows the type of connection in
use. It may be Serial or USB.
Country Line Setup:
Select the country in which Macrotel X1 or
Macrotel X2 is installed from this list. This parameter is important for
the configuration of the impedance set inside the Macrotel, which will
change and adapt the input telephone line with the line provided in
the country in which Macrotel is installed.
CPTD Signal Characteristics:
the
Call Progress Tone Detector
is
a function of the Macrotel which recognises if a call is still active or if it has ended. The CPTD characteristics vary from
country to country and the various parameters can be selected from the list.
UNDO:
press UNDO to reset the values set in the whole Hybrid 1, Hybrid 2 and Outputs section to
the values set on the device before the opening of the control panel. The Disconnect key
disconnects the device from the control software.