![Axcera Innovator CU10BT/CU0T-1 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/axcera/innovator-cu10bt-cu0t-1/innovator-cu10bt-cu0t-1_instruction-manual_3035948060.webp)
Innovator CU10BT-CU5000BT Analog Transmitter
Board Descriptions
Instruction Manual, Rev. 0
56
(A9 & A10) Power Supplies used in CU10, CU60, CU100, CU200 and Driver for
CU500 & higher power
Table 12: Model Number with corresponding (A10) Voltages and AC Input Voltages
MODEL
(A10) POWER SUPPLY VOLTAGE
AC INPUT VOLTAGE
CU10BT
+24VDC
115VAC or 230VAC
CU60BT
+28VDC
115VAC or 230VAC
CU100BT
+30VDC
115VAC or 230VAC
CU200BT
+40VDC
230VAC
CU200BT
w/888A Devices
+48VDC
230VAC
Voltages for the operation of the boards in the drawer are generated by (A9) a +5VDC
and ±12VDC power supply and (A10) a switching power supply which is a different
power supply providing a different voltage in each model. See the chart above. The
115VAC or 230VAC input to the CU10-CU200 drawer connects through the AC power
cord at J6, the power entry module located on the rear panel of the drawer.
The CU200 Drawer only operates with 230VAC. An On/Off 10A/250VAC circuit breaker
is part of the power entry module. With the circuit breaker switched On, the (L) line
input is wired to F1 a 10 Amp fuse for over current protection. The AC lines are
connected to terminal block TB1, which distributes the AC to (A9 and A10) the two DC
power supplies. There are two varistors, mounted on TB1, connected from the line input
to neutral and to ground for surge protection. The AC in the CU200 also connects to the
(A11) fan mounted on the rear panel of the Drawer. The fan will run when AC is applied
to the Drawer and the circuit breaker is switched On. The +5VDC and ±12VDC outputs
of the (A9) power supply connects to the terminal block (TB2) that distributes the DC to
the boards in the Drawer. Some of the +5VDC and ±12VDC outputs connect directly to
the Demodulator and Modulator boards while the other outputs connect through the CU
Control Board to the IF Precorrector, the Upconverter, the ALC, the Amplifier Assembly
and the Output Detector Boards.
The +24/+28/+30/+39VDC outputs of the (A10) power supply connect to the (A8) CU
Control Board, which then supplies the sw24/+28/+30/+39VDC to the (A6)
Amplifier Assembly. In CU3-CU50 Drawers the DC output of the (A10) power supply
also connects to the (A11) fan mounted on the rear panel, which will operate when AC is
applied to the Drawer, the On/Off circuit breaker is On and the (A10) power supply is
operating.
Circuit Description of External Board only used in CU2000 and higher power
Transmitters with multiple external amplifier Drawers
(A5) System Metering Board (1312666)
The function of the System Metering Board is to detect forward and reflected output power
samples and generate output voltages that are proportional to the power levels of the
sampled signals for use by the control monitoring assembly in the exciter/driver Drawer.
There are two identical signal paths on the board: one for forward power and one for
reflected power. A sample of the forward output power, from the external (A11) output
coupler, enters the board at the SMA jack J3. The signal is filtered and connected to
resistors R5, R3 and R6 that form an input impedance-matching network to Pin 3 on U1.
The forward power signal is detected by the RF detector IC U1. The detected output at
pin 7 is split with one half connected to the forward average calibration pot R7, which