![Axcera Innovator CU10BT/CU0T-1 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/axcera/innovator-cu10bt-cu0t-1/innovator-cu10bt-cu0t-1_instruction-manual_3035948020.webp)
Innovator CU10BT-CU5000BT Analog Transmitter
Unpacking, Installation
& Maintenance
Instruction Manual, Rev. 0
16
Table 1: CXB Series Analog Systems Typical AC Input and Current Requirements.
System
Output
Power
Power
Consumption
Voltage
Current
115 VAC
1.7 Amps to the Cabinet
CU10BT/CU0T-1
10 Watts
190 Watts
230 VAC
1 Amps to the Cabinet
115 VAC
2.7 Amps to the Cabinet
CU60BT/CU0T-2
50 Watts
310 Watts
230 VAC
1.4 Amps to the Cabinet
115 VAC
4.4 Amps to the Cabinet
CU100BT/CU0T-3
100 Watts
500 Watts
230 VAC
2.2 Amps to the Cabinet
CU200BT/CU0T-4
200 Watts
1000 Watts
230 VAC
4.3 Amps to the Cabinet
CU600BT/CU1T-1
600 Watts
1900 Watts
230 VAC
8.3 Amps to the Cabinet
CU1200BT/CU1T-2
1200 Watts 4000 Watts
230 VAC
17.4 Amps to the Cabinet
CU2500BT/CU2T
2500 Watts 7200 Watts
230 VAC
31.4 Amps to the Cabinet
CU3700BT/CU3T
3700 Watts 13000 Watts
230 VAC
56.6 Amps to the Cabinet
CU5000BT/CU4T
5000 Watts 17000 Watts
230 VAC
73.9 Amps to the Cabinet
Input and Output Connections
The input and output connections to the system are made to the jacks mounted on the rear
panels of the CU10 thru CU200 systems, the drivers for the CU500 and high power systems,
and to the 500 Watt and 1000 Watt amplifier Drawers. The CU10 thru CU200 systems and
the drivers for the CU500 and higher power systems accept baseband audio and video inputs
and output a RF ON Channel signal. Refer to Figure 3 and to Table 2 that follow for the
locations and information on the jacks and connectors.
Figure 3: Rear View CU10 thru CU200 and the driver for the CU500 and higher power
systems
Table 2: Connections for the CU10 thru CU200 and the driver for the CU500 & higher
power Systems
Port
Type
Function
Impedance
TB1
Terminals Balanced Audio Input
J1
BNC
Input A: Video Input
50 Ohms
J2
BNC
Input B: Composite Audio Input
50 Ohms
J6
BNC
10 MHz Input: Optional External 10 MHz Reference Input
50 Ohms
J9
N
RF Output: On Channel RF Output
50 Ohms
J10
IEC
AC Input: AC input connection to 85-264VAC Source and
On/Off circuit breaker
N/A
J11
9 Pos
Male D
Power Monitoring: Interface to System and external
amplifier Drawers, if present. Also provides an interlock for
the Reject Load (if used).
N/A
J1
J12
J10
J6
J9
J14
J13
J2
TB1
J11