Innovator CU10BT-CU5000BT Analog Transmitter
Unpacking, Installation
& Maintenance
Instruction Manual, Rev. 0
15
AC Input Connections
Refer to Figures 3 and 4 that follow for the location of the jacks and connectors of the system.
The CU10, CU60, and CU100 single Drawer systems will operate with an input voltage of 85-
253VAC. CU200 single Drawer systems operate on 185-253VAC. The customer should provide
a single point breaker or disconnect for the main AC input connection to the transmitter. Check
that the AC switch, located on the rear of the Drawer above the AC power jack, is OFF.
Connect the AC power cord supplied with the Drawer from J6 on the rear of the Drawer to the
AC source.
If your system is a CU500 or CU1000, it also contains one 500 Watt or 1000 Watt amplifier
Drawer. In CU2000 and higher power systems, multiple 1000 Watt amplifier Drawers are
included. Each amplifier Drawer is configured for 230 VAC operation only. Check that the
ON/OFF circuit breakers, located on each side of the AC power jack, are OFF. Connect the AC
power cord supplied with the Drawer from J10 on the rear of the Drawer to the 230 VAC source.
Refer to Table 1 for the typical voltage and current requirements for CXB Systems.
If the system is mounted in a cabinet, an AC distribution panel is used to connect the AC to the
individual Drawers. The AC distribution panel is mounted facing the rear of the cabinet and
accessed through the back of the cabinet. The main AC input for a CU2000BT transmitter is,
195-235VAC, at least 30Amps, 50/60Hz. The customer should provide a single point breaker or
disconnect for the main AC input that connects to the transmitter. The AC input lines connect
to the AC distribution panel by first removing the four #8 screws that hold the cover plate to
the front of the AC distribution panel. Then connect the three wire main AC input to the input
lugs located at the top left of the AC distribution panel, L1 to L1, L2 to L2 and Ground to the
Ground lug on the left.
The AC distribution panel has three circuit breakers that distribute the AC to the individual
Drawers, which are the Exciter and the two power amplifier Drawers, in the system. The circuit
breakers, which are accessed through the rear door of the cabinet, supply the AC though AC
line cords, that connect to the AC input jacks mounted on the rear panels of the Drawers. CB1
is a 30 Amp circuit breaker which supplies the AC to the (A2), top, Power Amplifier A Drawer.
CB2 is a 30 Amp circuit breaker which supplies the AC to the (A3), bottom, Power Amplifier B
Drawer. CB3 is a 10 Amp circuit breaker which supplies the AC to the (A1) Exciter/Driver
Drawer. The circuit breakers are accessed through the rear door of the cabinet.