Innovator CU10BT-CU5000BT Analog Transmitter
Initial On Site
Turn On Procedure
Instruction Manual, Rev. 0
33
NOTE:
Faulted amplifier sections are re-enabled when latched faults are
cleared in the event log. See Table 9.1 for more information on clearing
the logs.
Table 11.1.6: Chassis Values IF Processor Selection Screen
This screen, by selecting YES, indicates the IF Processor is required in
this system.
Table 11.1.7: Chassis Values Downconverter Selection Screen
This screen, by selecting NO, indicates the Downconverter is not
required in this system.
Table 11.1.8: Chassis Values Amplifier Power Supply Voltage Screen
This screen sets up the power supply voltage to match the amplifier
module present in your system.
NOTE:
Do not change this screen
without first consulting with Axcera.
Table 11.1.9: Chassis Values Minimum Forward Power Set Up Screen
This screen allows the user to set the Minimum Forward Output Power
level that the Transmitter will operate before the transmitter will report
a faulted condition.
NOTE:
If the transmitter system contains a back up
exciter, this screen can be used to set the level at which the back up
exciter will be activated.
Table 11.1.10: Chassis Values number of Amplifiers in System Screen
This screen sets up the number of amplifiers in your system.
NOTE:
Do
not change this screen without first consulting with Axcera.
Table 11.1.11: Chassis Values Ethernet Option Set Up Screen
If Ethernet is not present in your system this screen is displayed.
Table 11.1.12: Chassis Values Reset Ethernet User Name Set Up Screen
When the optional Ethernet Controller is present, this screen is
displayed. It is used to reset the first username / password account of
the Ethernet controller. There are a total a five accounts available on
the Web. If this operation is selected, ON, and the change accepted,
only the fist username / password account file is replaced, with the user
name set to ‘admin’ and the password set to ‘axcera’.