NOTE:
An example of accessing and changing an item using the Set Up Menus is as
follows. This procedure is to set the system to display automatically, the screen
indicating a faulted condition when it occurs using Table 10.1.3, the Chassis Values
Jump to Menu on Fault Set Up Screen. Push and release the DOWN Arrow button until
the TRANSMITTER SET UP Main Menu is displayed. Push and release the ENTER
button. The Authorization Warning screen is displayed. Push and release the ENTER
button again and the ENTER BUTTON SETS TO CHANGE MODE screen is displayed.
Push and release the ENTER button again and the first set up menu, which is the SET
UP CHASSIS VALUES screen is displayed. Push and release the ENTER button to
display the submenus under the SET UP CHASSIS VALUES menu. Push and release
the DOWN Arrow until the CHASSIS VALUES JUMP TO MENU ON FAULT SET UP
SCREEN is displayed. Push and release the ENTER button and the OFF, will blink.
Push and release the UP or DOWN Arrow button until ON is displayed. Push and
release the ENTER button, and the PUSH ENTER TO ACCEPT CHANGES menu is
displayed. Push and release the ENTER button again to accept the changes made.
The CHASSIS VALUES JUMP TO MENU is now set ON. Push and release the LEFT
Arrow to exit to the SET UP CHASSIS VALUES screen. Push and release the LEFT
Arrow again to exit to the TRANSMITTER SET UP Main Menu. Push and release the UP
or DOWN arrows to browse the main menus.
The following screens are typical of an operating system. The values indicated on the
screens in your system may vary from these.
Operation Screens
NOTE:
The following Operation screens provide operating information only. No
adjustments are available using these screens.
Table 8: Transmitter RF Power Screen
This is the default screen that is displayed after the splash screens are displayed. This
screen provides an indication of the Output Power of the system in terms of Percent.
(Typically 100%). The screen also provides an indication of the Reflected Power of the
system in terms of Percent. (Typically less than 5%). Push the DOWN Arrow to view
the next main menu, which is the System Fault Log Main Menu.
Table 9: Transmitter Event Log Main Screen
This is the System Event Log Main Screen. Push the ENTER button to access the Event
List submenu or push the DOWN Arrow to view the next main menu, which is the
System Details Main Menu.
Table 9.1: Event List Screen
When events occur, they will be displayed on this screen. The Up and Down
arrow will page you through the different entries in the event log. The above
screen indicates the 001 event of 013 total events that have occurred in the
Transmitter. The number in the parenthesis on the top right, is this case 01,
indicates the number of times the displayed event has occurred. The bottom
line scrolls to indicate the event that occurred, in this case RF Interlock Fault,
and the time the event occurred after the prior event. Push the LEFT Key to
exit to the Transmitter Event Log Main Menu screen. Pushing the RIGHT Key
will access the Event Reset Screen.