Innovator CU10BT-CU5000BT Analog Transmitter
Web Ethernet
Interface Description
Instruction Manual, Rev. 0
38
After logging in, the main control/monitoring screen is displayed. Administrators have
the ability to change the transmitter's operate / standby state, and configure the
application. All users have the ability to view the transmitter's event log, and review
system parameters. Refer to Figure 9 for a sample main control/monitoring screen.
Figure 9: Typical Ethernet Main Control/Monitoring Screen
Color Key:
Green = Okay or Normal Operation
Yellow = Warning, But Not faulted
Red = Currently Active Fault
Orange = Old or Previously Latched Fault
If an item on screen is Orange, a latched fault is present. Activating the
'Fault Reset'
button will reset any latched faults, clears the transmitter's event log and causes the
parameter to display normally.
The date and time of the last message received by the web page browser is present to
assure connectivity. If the browser does not receive a new set of data from the Ethernet
Controller, it will show the last update field with a yellow background indicating a
connection problem is present.