Table 10: Transmitter Details Main Screen
This is the System Details Main Screen. Push the ENTER button to access the Device
Details Chassis Values Main Sub Screen or push the DOWN Arrow to view the next
main menu, which is the System Set Up Main Menu.
Table 10.1: Transmitter Device Details Exciter Values Screen
This is the main submenu, which is the 8VSB Demodulator Sub Menu.
Table 10.1.1: Transmitter Driver Forward/Reflected Power Details
Screen
This screen provides an indication of the Output Power of the Driver
Drawer in terms of Percent, typically 20-70%. This screen provides an
indication of the Reflected Output Power of the Driver Drawer in terms of
Percent, Typically less than 3%.
Table 10.1.2: Heatsink Temperature Details Screen
This screen indicates the temperature of the amplifier heatsink
assembly, mounted in the system or driver Drawer, in degrees
Centigrade. If the temperature is below the trip point, it will indicate
OK. (Typically 15º to 20º C above ambient temperature)
Table 10.1.3: Power Supply Voltage Details Screen
This screen shows the power supply voltage in the system or driver
Drawer. If the power supply voltage is below the trip point, it will
indicate OK. (Typically 39V for a 100W Driver System the Voltage will
change for other power levels.)
Table 10.1.4: RF System Interlock Details Screen
This screen indicates if the external RF system interlock is present in
your system. (Typically Present. Must be present or system will remain
in Standby.)
Table 10.1.5: Reject Load Interlock Details Screen
This screen indicates if the external Reject Load interlock is present in
your system. (Connected to thermal switches on the reject loads from
the Output Combiner in systems with two or more External PAs. In
smaller systems is jumpered to ground. Must be present or system will
remain in Standby)