Synchronous operation:
- SYNCHRO mode. For a “Master” appliance, it starts synchronous operation of all paired appliances. For a “Slave” appliance, it restores synchronous
operation.
Additional buttons:
- SET button. It enables setting the clock timer, night mode operation time and resetting filter contamination counter.
- DISPLAY button. It changes the currently displayed information. Pushing the button toggles the following displays:
• Screen 1 - Display dimmed (dot flashing in the active ventilation mode and dot lit continuously in the off mode);
• Screen 2 - Flow dir speed + room humidity;
• Screen 3 - Flow dir speed + room temperature;
• Screen 4 - Clock;
• Automatic change - Sequential display of screens 2, 3 and 4 (changes every 5 seconds).
Functionality:
Clock setting:
• To enter the clock setting procedure, push the button and then (without releasing the button) push the button.
• A flashing clock showing the currently set time will appear on the screen.
• Set the current time using the (hours) and (minutes) buttons.
• To confirm the clock settings, push the button and then (without releasing the button) push the button.
Air filter operation time counter:
• After total 90 days of appliance operation, the following message will appear on the screen to inform that the filters require cleaning.
• This information will be displayed for a few seconds immediately after the appliance is turned on.
• After completing filter maintenance, reset the counter.
• To reset the counter, push the button and then (without releasing the button) push the button.
HIGRO mode:
• To activate this function, push the button on the remote controller. To change the set humidity threshold, toggle the button:
10%*
20%
30%
40%
50%
60%
70%
80%
90%
OFF (return to the home screen after 5 s)
*
if the HIGRO mode is currently enabled, the first push of the button will display the currently setpoint
.
• During operation in the HIGRO mode, the appliance compares the measured room humidity with the setpoint. The current speed of the appliance is based on
the following relationship:
- the measured value is smaller than the setpoint - fan off
- the measured value is 0-10% greater than the setpoint - speed 1
- the measured value is 10-20% greater than the setpoint - speed 2
- the measured value is 20-30% greater than the setpoint - speed 3
Note:
Changing the speed during operation in the HIGRO mode will cause switching to manual operation.
• The activation of the HIGRO mode is indicated by the flashing symbol on the screen of the appliance. Example:
TIMER mode:
• To activate this function, push the button on the remote controller. To change the set turn-off delay, toggle the button:
EN
12