• The appliance is compliant with IP22, electrical protection class II.
• The appliance must be operated according to its intended use and within the performance limits specified on the nameplate.
•
The connection of the fan to the fixed electrical system must be made with the 2x1.5 mm² VV-F 03H (OMY) cable with a maximum outside diameter
of 8 mm.
• Do not use the recuperator to pump air with the following content:
- viscous contaminants prone to deposition in the appliance;
- corrosive contaminants which may degrade the appliance,
- flammable contaminants, including gas, vapours, mists or particulates which may form explosive mixtures with air.
• The control system must prevent extremely frequent power cycling.
• The appliance must be installed in an external partition/wall, at a sufficient distance from pollution sources (chimneys, flue gas, etc.) to ensure pollution-free
drawn/supplied air.
• The ventilation duct should be installed with a slope of approx. 1% towards the outside.
The appliance must not be installed in a vertical position (in the
ceiling, roof).
• The appliance should be installed with the electrical compartment in the bottom.
Transport and storage
• Store the appliance in its original packaging, in a dry, sheltered room.
• The transport and storage ambient temperature limits are: -20°C to +40°C.
• Protect from impact and shock. Transport the appliance in its original packaging.
• For a storage time longer than 1 year, check if the rotor rotates freely before installation.
• The disposal of the appliance must be conducted properly, in accordance with environmental protection and waste management laws.
• Any damage caused by improper transport, storage or commissioning shall be proved and it is not covered by the warranty.
PRODUCT DESCRIPTION AND EQUIPMENT
Product description:
The AHR recuperator is equipped with a ceramic regenerative heat exchanger. The heat lost in the ventilation process can only be recovered in the
recuperation mode. The time of operation in the supply and exhaust direction is selected automatically based on readings from temperature sensors placed
within the appliance.
The AHR appliance is equipped with a bi-directional motor, with three rotational speeds.
Equipment
:
The kit consist of:
1. The AHR160 appliance
2. AHRTH wireless temperature/humidity sensor
3. Remote controller
4. Mounting dowels – 4 pcs.
Fig. 1
The appliance shall only be installed, connected to electrical mains and commissioned for use by qualified personnel in accordance with
applicable laws!
Recuperator installation procedure
• Precisely determine the appliance installation place.
• Prepare the power supply cable. Use
H03 VV-F (OMY) 2x1.5 mm² with a maximum diameter of 8 mm
.
5
3
1
6
7
2
2
4
8
9
10
DESIGN AND INSTALLATION
Basic appliance components:
1) Internal front panel
2) Air filters
3) Exchanger/motor block
4) Electronics cover
5) Internal body
6) Ventilation duct
7) External body
8) External front panel
9) AHRTH sensor cover
10) AHRTH sensor body
EN