maintained by the running capacitor which stays connected to the start winding.
Instructions for testing the items in the box are enclosed inside. Note: the running capacitance has
been changed from the 10
F supplied by Franklin to 20
F. This improves the power factor and
efficiency of the motor and reduces noise.
If relay contactor R1 is working properly and all the components in the Franklin box are OK, then an
inability of the pump to run properly indicates a problem with the submerged pump assembly.