44
DELAY
This variable sets the delay time for Limit 1 relay (high flow solenoid output)
relative to the START input. Typical delays are from 0.00 to 4.00 seconds. This
function is used in slow start applications where Limit 2 relay (low flow solenoid
output) is energized immediately at a START input and Limit 1 relay (high flow
solenoid output) is turned on after the DELAY time.
Enter the delay value desired for this batch to delay the Limit 1 relay output
activation on start using the DOWN – UP – SELECT buttons and press ENTER.
BATCH LIMITS
Enter the value desired for this batch to activate the Limit 1 relay output using
the DOWN – UP – SELECT buttons and press ENTER. In an identical manner
set the value for the S2 / Limit 2 relay output (batch total). Select the desired
engineering units for the display and press ENTER.
Continue to program all desired batch presets up to a total of 20. When finished,
return the Program / Run switch to the “RUN” position.
ANALOG OUTPUT
If your model was ordered with the 4-20 mA analog output option, one additional
mode is available to reflect the batch selected for remote monitoring. Selecting
the analog output for “Mode” will result in a current loop value directly proportional
to the batch number in use. Refer to the following table: