NOTE: Enabling the quadrature signal display will automatically disable all screens associated with
channel B as it is required that when using quadrature signals it can only be with one flow meter.
System Settings Programming
The system settings menu allows for the customization of the decimal places and
background color of the LCD display during limit operation.
Decimal Places
This sets the number of decimal places in the display for numerical values. The
choices are 1 through 3. Use the UP and DOWN buttons to adjust.
Screen Color Settings
Customization of the backlight for the LCD for the screen is available. Color
coding of the limit alarms can be useful for visual indication of totals reached or
rates that are out of tolerance. Default settings are green for normal operation,
blue for Limit one exceeded and red for limit 2 exceeded. Use ENTER to move
from line to line and SELECT to change colors as desired.
Calibrating Analog Output
The analog output can be calibrated to correct for any variances caused by the
users input equipment. The calibration routine allows the user to adjust the 4mA
and 20mA output values.
The calibration routine is entered from the STATUS screen.
NOTE: When entering the calibration routine, any incoming frequency to the MX 9000 is ignored.
Figure 26. System Settings Programming