42
is from 1 to 65534. The recommended typical range for values is from 200 to
2000. Initial value is 500.
BATCH TOTAL Programming
Use the BATCH TOTAL program mode to quickly dedicate both limits as total
limits and program the values at which the limits (labeled S1 and S2) activate.
1. Using the UP and DOWN keys, select the BATCH TOTAL display. Press
and hold the ENTER key. The display changes the first limit assignment S1
with a underlined cursor.
2. Enter a value to assign the limit as a total limit based on the engineering
units. Select the digit to edit using the SELECT key.
3. Use UP or DOWN keys to increase or decrease the value.
4. When the desired value displays, press ENTER to store and move the cursor
to S2.
5. Select the digit to edit using the SELECT key. Use UP or DOWN keys to
increase or decrease the value.
6. When the desired value is displayed, press the ENTER key to store and exit
the BATCH TOTAL program mode.
If either limit has been previously assigned to a function other than TOTAL A,
the MX 9000 will respond by asking “Limit mode different, want to change it?”
Use the YES or NO key to answer. A “YES” response resets any previous limit
assignment to Total A and zeros the limit value. A “NO” response leaves the
limit assigned to the previous function and the S1 or S2 display will read XXXX to
indicate that it has no function in this mode.
NOTE: The LCD backlight will change to blue when the total reaches the S1 set point and turn red
when it reaches the S2 set point. Backlight colors can be changed if desired. See system settings
programming on page 34.
To disable the batch total S1 and S2 limits you must reprogram the limits. See
page 27.
Batch Controller Programming
The batch controller model enables functions not found on the regular models and
is factory configured with a special option board to support these added functions.
Instead of just one batch set point found in the standard model, the batch
controller adds 19 more for a total of 20 batch presets. Most important are the 5
remote control line inputs which enable the electronics to select and process the
Содержание AW Gear Meters MX 9000
Страница 50: ...50 ...