MAIN MENU
46
3) PROTOCOL
Select
NORMAL
(our protocol),
P-D
(PELCO-D),
P-P
(PELCO-P),
S-T
(SAMSUNG-T) or
S-E
(SAMSUNG-E) protocol.
4) DEVICE
Select the baud rate for the connected speed dome camera (
2400
/
4800
/
9600
/
19200
/
38400
/
57600
/
115200
).
Make sure the baud rate setting of the camera is the same as the setting here, or the recorder will not be able
to control the device.
Note:
To know the default baud rate of the speed dome camera, please refer to its user manual.
5) INTERFACE
Select
RS485
if the connected speed dome camera uses RS485 wires to transmit control signals.
6.12 MAINTAIN
6.12.1 SYSTEM
SYSTEM
BACKUP CONFIG
SUBMIT
RESTORE CONFIG
SUBMIT
RESET DEFAULT
SUBMIT
DEVICE TITLE
dvr_1
ENABLE AUTO PLUG AND PLAY
ON
BIND MAC ADDRESS
OFF
1) BACKUP CONFIG / RESTORE CONFIG
To save the DVR current configurations for later use, such as restoring after DVR upgrade or applying to
another DVR, insert a compatible USB flash drive into the USB port, and select SUBMIT in
SUBMIT
in
BACKUP CONFIG
to copy the current DVR configurations to a file “System.bin” and save to your USB
flash drive.
To restore the DVR configurations, insert the USB flash drive including “System.bin” to the USB port, and
select
SUBMIT
in
RESTORE CONFIG
.
2) RESET DEFAULT
Click
SUBMIT
to reset all settings or partial settings to their factory default values, and select
YES
to
confirm or
NO
to cancel. The system will reboot after reset.
3) DEVICE TITLE
Enter a title for this device.
4) ENABLE AUTO PLUG AND PLAY
Switch to
ON
to allow the camera to be detected and configured automatically when it’s connected to this
device.
Note:
This function is available only when the brand of the cameras connected is the same as this
device.
5) BIND MAC
ADDRESS
This function is recommended to be used when your surveillance system is more than 256 cameras. It would
be helpful for the system to get the address of each connected camera quickly if the system accidentally
shuts down and needs to recover.