Shock sensor harness, 4-pin connector
H
GREEN
(-) MULTIPLEX INPUT, ZONE 2
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while
inputs longer than 0.8 seconds will trigger full alarm sequence and report Zone
Two. If installing an optional Directed Electronics dual stage sensor, connect to
the green wire as shown below. The diagram below eliminates the need for
diodes to isolate the sensors.
Diagram for adding optional Directed Electronics dual stage sensor to green
wire (Zone 2):
H
BLUE
(-) MULTIPLEX INPUT, ZONE 2
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while
inputs longer than 0.8 seconds will trigger full alarm sequence and will also
report Zone Two.
H
RED/BLACK
RED: is (+) 12V CONSTANT, BLACK is (-) GROUND
Do not use these for anything besides the plug-in shock sensor.