C - INSTALLATION
Solution with photocells:
view from above
post
post
rail
geared motor
rack
transmission photocell (TX)
reception photocell (RX)
swing
To avoid any risk of confinement in the gate clearance zone, the safety distances given in the diagram below
must be observed.
view from above
post
swing
8mm
max
stop
P
T
P = 500mm minimum if T is greater than 100mm
P = 200mm minimum if T is less than 100mm
On the upper runners
There is a risk of hands getting caught between the upper runners and the gate. To avoid this risk, the safety
distances given in the diagram below must be observed.
a
a
a
view from
above
view in profile
post
post
gate
gate
runner
runner
to < 8mm
Between the cog and the rack
There is a risk of hands getting caught between the cog and the rack. To avoid this risk, a protector (screen,
cover, etc.) must be placed on the geared motor. The safety distances given in the diagram below must be
observed.
CONNECTED MOTOR DRIVE KIT