![Avidsen 114461 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/avidsen/114461/114461_manual_3031446052.webp)
EN
52
G - TECHNICAL AND LEGAL INFORMATION
REMOTE CONTROL
Type
Type: OOK AM modulation. 16-bit Rolling code encoder
(i.e. 65,536 possible combinations)
Frequency
433.92MHz
Power supply
3V, CR2032 battery
Touch-sensitive
4 keys
Radiated power
< 10mW
Battery life
2 years at a rate of 10 x 2s uses per day
Operating temperature
-20°C/+60°C
Protection rating
IP40 (For indoor use only: home, car or sheltered
location)
PHOTOCELLS
Type
Modular infrared beam presence detector.
D type safety system according to EN 12453
Contents
1 TX transmitter and 1 RX receiver
Power supply
12 VDC, 12 VAC, 24 VDC, 24 VAC
Maximum assigned power
0.7W for the pair
Output
- 1 output with normally closed dry contact (COM/NC)
- 1 output with normally open dry contact (COM/NO)
Transmission angle/Reception angle
10° approx. / 10° approx.
Range
15m maximum (range may be reduced due to weather
disruption)
Operating temperature
-20°C/+60°C
Protection rating
IP44
CONNECTED MOTOR DRIVE KIT