C - INSTALLATION
4 - ATTACHING THE SET OF PHOTOCELLS
Important notes:
• The photocells must be perfectly aligned and parallel to each other.
• The reception photocells (RX is indicated at the back) must be installed at the same side of the
gate as the geared motor.
For the exterior photocells:
The surface of the posts where the photocells will be attached must be perfectly flat in order to properly align
the infrared beam of the photocells.
The photocells must be placed at a height of between 30 and 60cm from the ground.
30 cm min
60 cm max
outer side of the property
perfect alignment
10cm min/15cm
max
RX
view from above
outer side of the property
Mounting:
•
Mount the photocells on the posts.
•
Open the photocells by removing the 2 screw covers and the 2 screws.
•
Position the photocell in a vertical position in the location defined.
•
Mark the position of the two fastening holes and the position of the hole for the cable to run through.
45mm
20mm
CONNECTED MOTOR DRIVE KIT