AVG-CSK4K-44
8. Troubleshooting & Maintenance
Problems
Causes
Solutions
Colour loss or no video signal output
The connected cables may not be
connected correctly or faulty
Check whether the cables are
connected correctly and in working
condition
Failed or loose connection
Make sure the connection is secure
No output image when switching
No signal at input or output
Check with oscilloscope or multimeter if
there is any signal at the input/output
Failed or loose connection
Make sure the connection is secure
Input source contains HDCP while the
HDCP compliance is switched off
Send command /%[Y]/[X]:1. or change
the HDCP compliance status in the GUI
The display doesn’t support the input
resolution
Switch to another input source or enable
the display to learn the EDID data of the
input
Cannot control the device via the front
panel buttons
Front panel buttons are locked
Send command /%Unlock, or select
unlock in the GUI interface to unlock
Cannot control the device via the IR
remote
The battery has depleted
Replace battery
The IR remote is faulty
Send it to an authorized dealer for repair
Unit is beyond the effective range of the
IR signal or not pointing directly at the
IR receiver
Adjust the distance and angle and point
at the IR receiver
The IR receiver connected to IR IN port
does not contain IR carrier
Change to an IR receiver with carrier
Power Indicator remains off when
powered on
Failed or loose power connection
Check
whether
the
cables
are
connected securely
EDID management does not work
normally
The HDMI cable is broken at the output
end
Change to another HDMI cable which is
in good working condition
There is a blank screen on the display
when switching
The display does not support the
resolution of the video source
Manage the EDID data manually to
make the resolution of the video source
identical to the output resolution
Cannot control the unit with the control
device (e.g. a PC) through the RS232
port
Wrong connection
Check to ensure the connection
between the control device and the unit
Wrong RS232 communication
parameters
Enter the correct RS232 communication
parameters: Baud rate:9600, Data bit: 8,
Stop bit: 1, Parity bit: none
Faulty RS232 port
Send it to an authorized dealer for repair
Static
becomes
stronger
when
connecting the video connectors
Poor grounding
Check the grounding and make sure it is
connected well
Cannot control the device by RS232/IR
remote or front panel buttons
The device has a previous fault
Send it to an authorized dealer for repair