AVG-CSK4K-44
Command
Function
Feedback Example
Status.
Query the input channel to each output channel
one by one.
AV: 01->01
… …
AV: 04->04
IR: 01->01
… …
IR: 04->04
Save[Y].
Save the present operation to the preset
command [Y], range is from 0 to 9.
Save To FY (Y=0-9)
Recall[Y].
Recall the preset command [Y].
Recall From FY (Y=0-9)
Clear[Y].
Clear the preset command [Y].
Clear FY (Y=0-9)
PWON.
Work in
‘
normal
’
mode.
PWON
PWOFF.
Enter into standby mode and cut off the power
supply to HDBaseT receivers.
PWOFF
STANDBY.
Enter into standby mode. (Do not cut off the
power supply to HDBaseT receivers, press any
button or send commands to start.)
STANDBY
/%[Y]/[X]:[Z].
HDCP management command.
[Y] is for input (value: I) or output (value: O); [X]
is the number of the port, if the value of X is
ALL, it means all ports; [Z] is for HDCP
compliant status, the value may be 1 (HDCP
compliant) or 0 (not HDCP compliant).
/%[Y]/[X]:[Z].
DigitAudioON[x].
Enable HDMI audio output of port x.
X=1, 2, 3, 4, enable this port.
X=5, enable all the 4 ports.
DigitAudio ON with [x]
DigitAudioOFF[x].
Disable HDMI audio output of port x.
X=1, 2, 3, 4, disable this port.
X=5, disable all the 4 ports.
DigitAudio OFF with [x]
EDIDH[x]B[y].
Input port [y] learns the EDID from output port
[x].
If the EDID data is available and the audio
section supports not only PCM mode, then
force-set it to support PCM mode only. If the
EDID data is not available, then set it as
initialized EDID data.
EDIDH[x]B[y]
EDIDPCM[x].
Set the audio section of input port [x] to PCM
format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and display the
output port number.
Hexadecimal EDID data
and
carriage
return
character
EDIDMInit.
Restore the factory default EDID data of every
input.
EDIDMInit.
EDIDM[X]B[Y].
Manual EDID switching. Enable input[Y] to
learn the EDID data of output[X]. If the EDID
data is not available, then set it as initialized
EDID data.
EDIDM[X]B[Y]
EDIDUpgrade[x].
Upgrade EDID data via the RS232 port.
[x] is the input port, when the value of X is 9,
this will upgrade all input ports. When the
switcher receives the command, it will show a
message to prompt you to send an EDID file
(.bin file). Operations will be canceled after 10
seconds. Please disconnect all HDBaseT ports.
Please send the EDID
file
EDID/[x]/[y].
Set the EDID data of input port [x] to built-in
EDID No.[y].
EDID/[x]/[y]