ZQ375 Checkweigher User Instructions
85
7.3 Supervisor menu for Adv375 application
40.
Press
or
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
A-tArE
is displayed.
Reset
Check
Outputs
Out-gzb
USegDiv
OSegDiv
Prt tot
Tot Fmt
Clr Tot
Digits
Graph
Stats
Packrun
Type
A-tare
Reset
41.
Press
UNITS
to go to the next menu item …
rESEt
is displayed. Use this to reset the factory defaults for the
checkweighing parameters.
42.
Press
SELECT
…
no
is displayed. This is the default value.
43.
Press
ZERO
to abort the reset or, to reset the defaults, press
UNITS
…
YES
is displayed. Accepting this will reset the defaults.
44.
Press
ZERO
to accept …
The defaults are reset and
rESEt
is displayed.
45.
Press
TARE
…
chEcK
is displayed.
7.3.4 PLU
Super
Setpoint
Tare
Check
Plu
1.
Press
UNITS
to go to the next menu item …
PLu
is displayed. This stand for Product Look Up. Use this to edit the
PLU list, print the list or reset the PLUs to factory defaults.
PLUs consist of a sequential number as an identifier, a target weight, a
target-low weight and a target-high weight.
Edit
PLU
Edit
2.
Press
SELECT
…
Edit
is displayed. Use this item to setup the PLU list.
3.
Press
SELECT
…
A numeric entry screen appears with a flashing
0
.