66
ZQ375 Checkweigher User Instructions
Supervisor menu
Inputs
Setpoint
Edit
Annun
Inputs
6.
Press
UNITS
…
in1
is displayed. This stands for input 1. Use this to assign a function to
input 1 when an external switch is tripped. Default choice is
nonE
. The
choices are listed in
. Some may not apply in this application.
7.
From
in1
, press
SELECT
…
The current choice is displayed.
8.
Press
or
UNITS
to scroll through the choices and when your choice is
displayed, press
ZERO
to accept …
in1
is displayed.
9.
Press
UNITS
…
in2
is displayed.
10.
Repeat steps
in2
and
in3
. Press
TARE
when finished …
Edit
is displayed.
Setpoint
Edit
11.
Press
UNITS
…
is displayed. Use this to print the settings under
SEtPnt
.
12.
Press
SELECT
…
Port 1
is displayed.
13.
Press
F1
to abort the print process or press
UNITS
to scroll to the desired port
and press
ZERO
to print the information …
is displayed after either action.
Reset
Setpoint
Edit
Reset
14.
Press
UNITS
…
rESEt
is displayed. Use this to reset the settings under
Edit
to factory
defaults.
The remote input can be used to perform an accumulated print total function. Use the
PrintHoLd
function to simulate a “press and hold” of the
key. If you are using
a momentary switch, press and release. If you are using a toggle switch, switch it ON
then OFF to reset the function for the next time.