Example: annunciators lit when acceptable limits are: LO < 1.00 kg and HI > 4.00 kg
3.4.1. Setting the Checkweighing Limits
i. When the scale is ON, press
and
TARE
keys together;
UF-1
will be displayed
.
ii. Press
TARE
(
►
) key;
UF-2
will be displayed.
iii. Press
(
↵
) key;
iv. Enter or edit the
LO
limit value by pressing
ZERO
(◄) and/or
TARE
(►) keys to move the flashing digit left or right and press the
SELECT
(▲) key to increase the numeric value;
v. Press
(
↵
) key
to confirm;
vi. Repeat points
iv.
and
v.
for the
HI
limit;
vii. Choose the
beeper mode
[
000; 001; 002;
See Section 3.3.2
] by
pressing
ZERO
(◄) and/or
TARE
(►) keys to move the flashing
digit left or right and press the
SELECT
(▲) key to increase the
numeric value;
viii. Press
(
↵
)
key to complete and leave the procedure;
ix. Press
UNITS
(
ESC
)
key to exit the User Menu.
To disable the checkweighing feature, set the LO limits to 0 in the User Menu [UF-2].
The LO and HI annunciators may vary. The illustration shows the annunciators displayed when
acceptable limits are entered for first time.
3.3.2. Checkweighing Beeper Modes
There are three beeper modes.
o 000
The beeper is disabled.
o 001
The beeper tones only when the load is within the acceptable limits.
o 002
The beeper tones only when the load is outside the acceptable limits.
Please, ignore any other mode not listed above.
3.5. Hold Mode for Animal Weighing
Hold mode is not available in this model.