03/10 Rev. 5.05-00
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
56
EasyPlug error
AP 5.4
AP 5.6
Handling of errors caused by faulty Easy-Plug commands.
Tolerant handl.
The label is printed, after the Easy-Plug/Bitimage error was acknowledged
(default setting).
Strict handling
The Easy-Plug command, which caused the error, is displayed after approx.
2 seconds in the lower display line. The displayed text is up to 30 characters
long and is scrolled automatically.
If a single character caused the error, this character is marked with „>> <<„
in the display text, to facilitate the detection.
By pressing the cut button, the display can be toggled between error mes-
sage and Easy-Plug command text.
After acknowledging the first occured Easy-Plug error, the printjob and the
spooler are deleted (as by #!CA). This prevents the printing of labels with for-
mat errors.
Single job mode
AP 5.4
AP 5.6
In single job mode (also stop mode) the printer stops after every job and waits
until the operator restarts the print process.
Deactivated
Single job mode is switched off (default setting).
Activated
Single job mode is switched on. The printer always displays "Start next job",
before starting a new print job. This requests the user to acknowledge by
pressing the Online button.
Head resistance
AP 5.4
AP 5.6
For optimum print quality, the individual print head resistance of the thermo
head employed in the device must be set once with this parameter.
When replacing the print head, the resistance value of the print head (to be
read off from the print head) must be entered again.
¯
CAUTION! - Entering a false value can damage the print head!
«
Read off the correct value from the print head and set it accordingly.
¯
The value set here remains when the factory settings are carried out.
xxxx Ohm
Setting range: 1000 to 1500 Ohm; Unit interval: 1 Ohm
Setting the print head resistance: