Character filter
AP 5.4
AP 5.6
Character >= 20Hex
Filter function is activated. Characters smaller than 20H are filtered out of the
data flow.
All character
Filter function is deactivated. Characters smaller than 20H are treated as nor-
mal characters.
Light sens. type
AP 5.4
AP 5.6
Light sensor type
The optional reflex photoelectric switch for labels with reflecting length mark-
ings, or the normal factory-fitted photoelectric switch for labels with transpar-
ent or register gaps (self-adhesive labels), must be defined according to the
application.
Short label opt.
Activates the optional short label sensor.
¯
Appears only in AP 5.4 printers which are equipped with the short label
sensor.
Reflex
Reflex photoelectric switch (for reflecting markings)
Punched
Transparent photoelectric switch (for gaps)
Head-sensor dist.
AP 5.4
AP 5.6
¯
Parameter appears only in production mode or if a value > 0 is set.
Printhead-sensor distance
Special function for setting non-standard punch sensors. Such sensors can
be applied in special application devices ("Nistan"). The value x is the dis-
tance between thermal edge and punch sensor in millimeters.
x mm
Setting range: 0 to 400 mm
¯
A „non standard sensor“ must be installed and connected instead of the
regular punch sensor.
¯
0 = disabled (the regular punch sensor is used).