Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
30
Punch offset
AP 5.4
AP 5.6
The zero position can be determined offset in millimetre units from the detect-
ed gap position.
¯
The value is overwritten by the appropriate Easy Plug command when
sending label formats.
xxx mm
Setting range: -8 to +max. label length; Unit interval: 0,1mm
Default setting: 0 mm
Maximum offset in feed direction: -8 mm
Minimum offset against feed direction: +max. label length
[10] Positive and negative offset in relation to the feed direction (arrow).
Bar code multip.
AP 5.4
AP 5.6
Bar code height scaling factor
Increases the bar code height defined in the label layout (Easy-Plug) by multi-
plication by a factor of 1 to 10.
x
Setting range: 1 to 10; Unit interval: 1; Default setting: 1
The printed bar code height calculates starting with the value defined in the
label layout multiplied by the scaling factor x.