03/10 Rev. 5.05-00
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
75
Min. rew. current
AP 5.4
AP 5.6
¯
Only in production mode.
¯
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Minimal rewinder current
This parameter influences the rewinder current with 25 mm rewinder dia-
meter (min. rewinder diameter).
XXX%
Setting range: 50-200%; Default setting: 100%
Precondition for the setting in percent:
Parameter
DISPENSER PARA > Current mode = Table values
(see above).
XXX
Setting range: 0-750; Default setting: 100;
Precondition for the setting in absolute values:
Parameter
DISPENSER PARA > Current mode = Absolute values
(see above).
Max. rew. current
AP 5.4
AP 5.6
¯
Only in production mode.
¯
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Maximum rewinder current
This parameter influences the rewinder current with 120 mm rewinder dia-
meter (max. rewinder diameter).
XXX%
Setting range: 50-200%; Default setting: 100%
Precondition for the setting in percent:
Parameter
DISPENSER PARA > Current mode = Table values
(see above).
XXX
Setting range: 0-750; Default setting: 250;
Precondition for the setting in absolute values:
Parameter
DISPENSER PARA > Current mode = Absolute values
(see above).
The two parameter values
Min. rew. current
and
Max. rew. current
are used
by the motor output stage to calculate all other current values for diameters
lying in between.
Problem
Solution
The label web runs too loose around the dispensing edge
during printer operation.
The label roll is wound up too loose.
Increase the setting
The label web runs too tight around the dispensing edge
during printer operation.
The label roll is wound up too tight.
Decrease the setting
[6]
Cases, in which the setting of the minimal rewinder current has to be corrected.