Datalogic QuickScan QS6500 Скачать руководство пользователя страница 1

QuickScan

®

 QS6500/QS6500BT

Product Reference Guide

Содержание QuickScan QS6500

Страница 1: ...QuickScan QS6500 QS6500BT Product Reference Guide...

Страница 2: ...e revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www scann...

Страница 3: ...on 3 4 LED and Beeper Indicators 3 6 Power On Alert 3 6 LED Idle State 3 6 Good Read When to Indicate 3 7 Good Read Beep Control 3 8 Good Read Beep Frequency 3 8 Good Read Beep Length 3 9 Good Read Be...

Страница 4: ...ulation 4 34 Supported Symbologies 4 34 Wand Emulation Bar Code Format 4 34 Bar Space Polarity 4 35 Initial Polarity 4 35 Signal Speed 4 36 Transmit Trailing Noise 4 36 Transmit Leading Noise 4 37 Sym...

Страница 5: ...e Leading Ending 6 33 Code I D Selection 6 34 Example Setting the EAN 8 Code I D 6 34 EAN 8 Data Group Characters 6 36 Add ons 6 38 GTIN 6 40 Disable Enable GTIN 6 40 Code I D Selection 6 40 Example S...

Страница 6: ...I D 6 76 Pharmacode 39 Data Group Characters 6 78 Code 128 6 80 Disable Enable Code 128 6 80 Checksum Verification 6 80 Checksum Transmit 6 80 Function Code Transmission 6 80 Minimum Maximum Code Leng...

Страница 7: ...Start End Type 6 123 Start End Transmission 6 123 Code 93 6 124 Disable Enable Code 93 6 124 Checksum Verification 6 124 Checksum Transmit 6 124 Minimum Maximum Code Length 6 126 Truncate Leading Endi...

Страница 8: ...Selection 6 168 Example Setting the Standard 2 of 5 Code I D 6 168 Standard 2 of 5 Data Group Characters 6 170 Code 16K 6 172 Disable Enable Code 16K 6 172 Truncate Leading Ending 6 173 Code I D Sele...

Страница 9: ...th Features 7 1 Auto Update 7 1 Deep Sleep Mode 7 3 Leash Alarm 7 4 Bluetooth Connectivity Mode 7 6 Inquiry Beep Control 7 8 Chapter 8 Product Specifications 8 1 Imager Product Specifications 8 1 Stan...

Страница 10: ...viii QuickScan QS6500 QS6500BT Bluetooth Imager Indications F 1 Bluetooth Base Station Indications F 3 Appendix G Sample Symbols G 1 Sample Symbols for PDF Models ONLY G 2...

Страница 11: ...unces 160 grams and has an ergonomic comfort grip for ease of use About This Manual This Product Reference Guide PRG contains the information listed below For installation maintenance troubleshooting...

Страница 12: ...nter face Default exceptions for other interfaces are listed in Appendix D Nomenclature Figure 1 1a illustrates the features of the corded version of the linear imager and Figure 1 1b represents the B...

Страница 13: ...pro gramming is accomplished by scanning the bar codes in this guide In the programming chapters factory default settings are indicated with bold text and yellow highlighting These defaults represent...

Страница 14: ...Getting Started 1 4 QuickScan QS6500 QS6500BT NOTES...

Страница 15: ...the imager in the Base Station for one minute to get a small charge in the battery 4 Read the label on the Base Station with the imager The imager will sound a good read beep and the LED will flash am...

Страница 16: ...ase Station Pushing the but ton on the Base Station while the imager is in range will break the link between the devices If the button is pushed while the imager is out of range the Base Station will...

Страница 17: ...taking place the charging LED marked with a battery symbol will blink green When the battery is fully charged the charging LED will stay on a solid green If there is an error in charging either with a...

Страница 18: ...Bluetooth Models 2 4 QuickScan QS6500 QS6500BT NOTES...

Страница 19: ...The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again e g two identical items in succes sion START DURATION BARCODE 0 1 Second 0...

Страница 20: ...General Features 3 2 QuickScan QS6500 QS6500BT 0 9 Second 1 Second END START DURATION BARCODE...

Страница 21: ...The Imager Timeout feature sets the time for automatically switching the unit off when the imager is not in use START DURATION BARCODE 1 Second 2 Seconds 3 Seconds 4 Seconds 5 Seconds 6 Seconds 7 Sec...

Страница 22: ...4 QuickScan QS6500 QS6500BT Read Verification Sets the number of times a bar code must be read before it is transmitted 13 Seconds 14 Seconds 15 Seconds END START of TIMES BARCODE None 1 2 3 4 5 STAR...

Страница 23: ...Read Verification Product Reference Guide 3 5 6 7 8 9 END START of TIMES BARCODE...

Страница 24: ...nables the indication LED and or Beeper that the imager is receiving power LED Idle State This feature specifies the state of the green scanner LED when the scan ner is idle and ready to read a label...

Страница 25: ...or flash its green LED upon successfully reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active NOTE T...

Страница 26: ...y to beep upon a success ful decode of a label Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the bee...

Страница 27: ...cators Product Reference Guide 3 9 Good Read Beep Length Specifies the duration of a good read beep 2500 Hz 2600 Hz 2700 Hz 2800 Hz 2900 Hz END START LENGTH BARCODE 60msec 80msec 100msec 120msec START...

Страница 28: ...General Features 3 10 QuickScan QS6500 QS6500BT 140msec 160msec 180msec 200msec END START LENGTH BARCODE...

Страница 29: ...Volume Selects the beeper volume loudness upon a good read beep There are five selectable volumes with each volume increment adding approxi mately five decibels to the previous level START VOLUME BAR...

Страница 30: ...elapsed Momentary The trigger acts as a switch Pressing the trigger activates scanning releasing it stops scanning Alternate The trigger acts as a toggle switch Pressing the trigger activates scanning...

Страница 31: ...Scanning Imaging Features Product Reference Guide 3 13 Scan Mode continued START MODE BARCODE Good read off Momentary Alternate Timeout off Stand mode END...

Страница 32: ...cases the illumination LEDs come back on when something passes in front of the imager Scan Illumination LED Timeout Limits the time following pressing the trigger that the illumination LED aiming ligh...

Страница 33: ...de 3 15 Inverted Image Scan With this option enabled the imager will scan black white bar codes with a white black background 90 Seconds 120 Seconds 150 Seconds 180 Seconds Continue END START MODE BAR...

Страница 34: ...value for both minimum and maximum lengths to force decoding of only fixed length bar codes This setting has no effect on certain symbologies of fixed length START MODE BARCODE Global Minimum length c...

Страница 35: ...both minimum and maximum lengths to force decoding of only fixed length bar codes This setting has no effect on certain symbologies of fixed length START MODE BARCODE Global Maximum length can be set...

Страница 36: ...General Features 3 18 QuickScan QS6500 QS6500BT NOTES...

Страница 37: ...Imager supports the interfaces listed in Table 4 1 Select the desired interface type from the table then reference the page number given for the customizable features section associated with each inte...

Страница 38: ...dge Pa 4 27 USB Keyboard 4 25 Keyboard Wedge Qa 4 27 Keyboard Wedge Keyboard Wedge Ra 4 27 Keyboard Wedge Aa a Consult Table 4 2 for more information regarding keyboard wedge inter face types 4 27 Key...

Страница 39: ...25 Style IBM Enhanced PC M WYSE 60 85 99 GT 150 160 285 ANSI Keyboard 105 Keys 520 520 ES ANSI Keyboard 105 Keys WYSE 55 65 65 ES 120 185 325 ANSI Keyboard 105 Keys N WYSE 60 85 99 GT 150 160 285 ASCI...

Страница 40: ...4 QuickScan QS6500 QS6500 BT Interface Selection START STATE BARCODE RS 232 Standard RS 232 Wincor Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 IBM USB USB Keyboard Keyboard Wedge A Keyb...

Страница 41: ...Reference Guide 4 5 Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G Keyboard Wedge H Keyboard Wedge I Keyboard Wedge J Keyboard Wedge K Keyboard Wedge L Keyboard Wedge M Keyboard...

Страница 42: ...es 4 6 QuickScan QS6500 QS6500 BT Keyboard Wedge O Keyboard Wedge P Keyboard Wedge Q Keyboard Wedge R Keyboard Wedge S Keyboard Wedge T Keyboard Wedge U Keyboard Wedge V Keyboard Wedge W Keyboard Wedg...

Страница 43: ...Interface Selection Product Reference Guide 4 7 Keyboard Wedge Y Wand Emulation END START STATE BARCODE...

Страница 44: ...QuickScan QS6500 QS6500 BT Interface Features Global Interface Features START STATE BARCODE Obey Host Commands Ignore Host Commands Disable Debug Mode Enable Debug Mode Host Transmission Buffers 1 Ho...

Страница 45: ...Interface Features Product Reference Guide 4 9 RS 232 Interface Features START STATE BARCODE 1200 Baud 2400 Baud 4800 Baud 9600 Baud 19200 Baud 38400 Baud 57600 Baud 115200 Baud...

Страница 46: ...Interface Related Features 4 10 QuickScan QS6500 QS6500 BT RS 232 Interface Features cont START STATE BARCODE 7 Data Bits 8 Data Bits 1 Stop Bit 2 Stop Bits Parity None Parity Even Parity Odd END...

Страница 47: ...and transmit data While the CTS line is inactive the imager remains in a host disabled state following a successful label transmis sion the CTS signal must transition to inactive and then to active to...

Страница 48: ...sable Hardware Control Enable CTS Flow Control Enable CTS Scan Control Inter Char Delay No Delay Interchar Delay 10 msec Interchar Delay 20 msec Interchar Delay 30 msec Interchar Delay 40 msec Interch...

Страница 49: ...Interface Features Product Reference Guide 4 13 Disable Software Flow Control Enable Software Flow Control END RS 232 Interface Features cont START STATE BARCODE...

Страница 50: ...the host the scanner will wait for the RS 232 chan nel to be quiet for a specified period of time set via RS 232 Host Echo Quiet Interval The scanner can be set to observe this delay before send ing i...

Страница 51: ...st Echo Host Echo Quiet Interval 0msec Host Echo Quiet Interval 10msec Host Echo Quiet Interval 20msec Host Echo Quiet Interval 30msec Host Echo Quiet Interval 40msec Host Echo Quiet Interval 50msec H...

Страница 52: ...condition is detected by the host ACK NAK Options This enables disables the ability of the imager to support the RS 232 ACK NAK protocol When configured the imager and or host sends an ACK when it rec...

Страница 53: ...mager will respond with ACK NAK when the host sends a command Enable for label transmission and host command acknowledge START STATE BARCODE Disable Beep on ASCII BEL Enable Beep on ASCII BEL Disable...

Страница 54: ...e this feature scan the START bar code above to place the unit in Programming Mode then the Set ACK Character followed by the digits from the Alphanu meric table in Appendix B Alpha Numeric Pad repres...

Страница 55: ...feature scan the START bar code above to place the unit in Programming Mode then the Set NAK Character followed by the digits from the Alphanu meric table in Appendix B Alpha Numeric Pad representing...

Страница 56: ...BT RS 232 Interface Features cont Retry on ACK NAK Timeout Enables disables retry after the configurable ACK NAK Timeout Value set in the following feature has expired START STATE BARCODE Disable Retr...

Страница 57: ...in 200 millisecond increments To configure this feature scan the START bar code above to place the unit in Programming Mode then the Set ACK NAK Timeout Value followed by the digits from the Alphanume...

Страница 58: ...number of times 255 Retry forever To configure this feature scan the START bar code above to place the unit in Programming Mode then the Set ACK NAK Retry Count followed by the dig its from the Alpha...

Страница 59: ...om the host Errors include unrecognized host commands and communication errors such as parity or framing errors Choices are 00 Ignore errors detected recommended setting 01 Process error as valid ACK...

Страница 60: ...QS6500 QS6500 BT RS 232 Interface Features cont Transmission Failure Indication Enables disables bad label indication upon transmission failure START STATE BARCODE Disable Transmission Error Indicatio...

Страница 61: ...entified as one of two different types of bar code scanners Depending on what other scan ners you may already have connected to a IBM USB POS you may need to change this setting to enable all devices...

Страница 62: ...bility to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host This applies to Code 128 Coda bar and Code 93 for IBM USB Code 128 Codabar and...

Страница 63: ...require any changes of software or hardware Keyboard Layout The Keyboard Layout option supports many countries For details about Keyboard Layout please refer to your operating system manual NOTE All o...

Страница 64: ...Interface Related Features 4 28 QuickScan QS6500 QS6500 BT Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech Slovakia Romania END START STATE BARCODE...

Страница 65: ...Features Product Reference Guide 4 29 Keyboard Wedge USB Keyboard cont Caps Lock State Specifies which format the imager sends character data START STATE BARCODE Disable Caps Lock Caps Lock ON Shift L...

Страница 66: ...tus to the PC during power on Control Characters Specifies how the imager transmits ASCII control characters to the host Choices are Disable Control Characters Enable transmission of control character...

Страница 67: ...eference Guide 4 31 Keyboard Wedge USB Keyboard cont START STATE BARCODE Disable Power on Simulation Enable Power on Simulation Disable Control Characters Enable Transmission of Control Characters Ena...

Страница 68: ...00 no interval to 255 in 10 msec increments Use hexidecimal range 00 to FF hexidec imal to set the interval To configure this feature scan the START bar code above to place the unit in Pro gramming Mo...

Страница 69: ...the system work prop erly Selectable from 00 to 255 in 10msec increments Use hexidecimal range 00 to FF hexidecimal to set the delay To configure this feature scan the START bar code above to place th...

Страница 70: ...ettings are required for the wand emulation inter face These settings have been pre configured at the factory for Wand Emulation scanners UPC A bar codes must include all 12 digits UPC E bar codes mus...

Страница 71: ...h level 5 High Low Black will be transmitted as a high voltage level 5 and space as low level 0V Initial Polarity The idle polarity of the wand decode device can be set with the following options High...

Страница 72: ...ansmission can be set This selects the width of the minimum narrow bar 330 microseconds 660 microseconds Transmit Trailing Noise The transmission of noise pulses after the label may be enabled or dis...

Страница 73: ...code may be enabled or disabled Symbology Conversion Wand Emulation can convert all bar codes to a single symbology Choices are No Conversion Convert to Code 39 Code 39 Full ASCII Convert to Code 128...

Страница 74: ...Interface Related Features 4 38 QuickScan QS6500 QS6500 BT NOTES...

Страница 75: ...ON It is not recommended to use these features with IBM 46xx or IBM interfaces Prefix 00 22 Characters ASCII Sufffix Symbology ID ID Preamble Postamble Bar Code Data Code Length Insert Groups Code Len...

Страница 76: ...features in this chapter You can add any prefix or suffix from Appendix A ASCII Conversion Chart plus Code I D AIM I D Several entries for several symbologies can be strung together at one time Enter...

Страница 77: ...3 Scan the SET PREFIX CHARACTER S bar code 4 Reference Appendix A ASCII Conversion Chart to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To...

Страница 78: ...e unit in Programming Mode then the Set Prefix or Set Suffix followed by the digits from the Alphanumeric table in Appendix B Alpha Numeric Pad representing your desired character s Refer ence the sec...

Страница 79: ...postamble 2 Scan the START bar code 3 Scan the SET POSTAMBLE CHARACTER S bar code 4 Reference Appendix A ASCII Conversion Chart to find the hex value assigned to the desired character The correspondin...

Страница 80: ...LE followed by the digits from the Alphanumeric table in Appendix B Alpha Numeric Pad representing your desired character s Reference the section Example Set ting a Postamble for more information Acce...

Страница 81: ...Data Editing Overview Product Reference Guide 5 7 Transmit Postamble SET END START MODE BARCODE...

Страница 82: ...lowing the transmitted bar code data depending upon how this feature is enabled In addition to message string positioning before or after bar code data options for this feature include Disable Proprie...

Страница 83: ...This function is used to identify and display the scanned bar code s symbology from among any of the symbologies readable by the imager When enabled the code name symbology will be transmitted before...

Страница 84: ...BARCODE Disable Symbology Name Enable Symbology Name Code I D Position Before Bar Code Data Code I D Position After Bar Code Data Code I D Transmission Disable Code I D Transmission Proprietary I D Co...

Страница 85: ...code 4 In this step we select the three spaces from the left position in which to place the characters we ll select later Scan first the 0 zero bar code then the 3 bar code from the numeric digit bar...

Страница 86: ...it Programming Mode 7 Data Group Characters are configured individually for each sym bology type enabling or disabling the Data Groups you ve created using the options provided in the Symbologies chap...

Страница 87: ...Overview Product Reference Guide 5 13 Set Group 2 Character s Set Group 3 Position Set Group 3 Character s Set Group 4 Position Set Group 4 Character s SET END Data Group Characters continued START M...

Страница 88: ...ert scanned bar code data to either all lower case or all upper case characters NOTE Case conversion affects ONLY scanned bar code data and does not affect Code I D Preamble Postamble or other appende...

Страница 89: ...y support these sym bologies Factory Defaults are indicated in bold text and are highlighted with yellow throughout this section UPC A Interleaved 2 of 5 UPC E Industrial 2 of 5 EAN 13 Matrix 2 of 5 E...

Страница 90: ...ill not read UPC A bar codes Checksum Transmission Enable this option to transmit the checksum along with UPC A bar code data Expand UPC A to EAN 13 Enable this option to add a leading zero to a UPC A...

Страница 91: ...UPC A Product Reference Guide 6 3 UPC A continued START STATE BARCODE Disable UPC A Enable UPC A Don t Send Checksum Send Checksum No Expansion ExpandUPC A to EAN 13 END...

Страница 92: ...rs to truncate from either the leading or ending characters of scanned bar code data To configure this fea ture scan the START bar code above to place the unit in Program ming Mode then the SET TRUNCA...

Страница 93: ...o represent UPC A The value from the table corresponding to A is 41 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET UPC A CODE I D bar code 4 Turn to Appendix B Al...

Страница 94: ...gies 6 6 QuickScan QS6500 QS6500 BT UPC A continued START STATE BARCODE Set UPC A Code I D Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex Select 0000 to disable Code ID for this symbology only...

Страница 95: ...HARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group For exa...

Страница 96: ...Symbologies 6 8 QuickScan QS6500 QS6500 BT UPC A continued START STATE BARCODE Set UPC A Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 97: ...read the main portion of the bar code 2 Digits The imager will read 2 digit add ons with the UPC A label 5 Digits The imager will read 5 digit add ons with the UPC A label 2 and 5 Digits The imager wi...

Страница 98: ...Symbologies 6 10 QuickScan QS6500 QS6500 BT UPC A continued START STATE BARCODE None 2 Digits 5 Digits 2 5 Digits UCC EAN 128 2 Digit UCC EAN 128 5 Digit UCC EAN 128 All END...

Страница 99: ...ally a zero 0 in the leading position can be truncated excluded from scanned bar code data Expand UPC E to EAN13 Adds a leading zero to a UPC E bar code which expands the data to the EAN 13 data forma...

Страница 100: ...ickScan QS6500 QS6500 BT UPC E continued START STATE BARCODE Disable UPC E Enable UPC E Don t Send Checksum Send Checksum Truncate NSD Expand to EAN 13 NONE Truncate NSD Expand UPC E to EAN 13 Expand...

Страница 101: ...o truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCATION...

Страница 102: ...I D of E to represent UPC E The value from the table corresponding to E is 45 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET UPC E CODE I D bar code 4 Turn to App...

Страница 103: ...E Product Reference Guide 6 15 UPC E continued START STATE BARCODE Set UPC E Code I D Character s DEFAULT SETTING FOR THIS FEATURE E 45 hex Select 0000 to disable Code ID for this symbology only SET...

Страница 104: ...OUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group Fo...

Страница 105: ...UPC E Product Reference Guide 6 17 UPC E continued START STATE BARCODE Set UPC E Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 106: ...till read the main portion of the bar code 2 Digits The imager will read 2 digit add ons with the UPC E label 5 Digits The imager will read 5 digit add ons with the UPC E label 2 and 5 Digits The imag...

Страница 107: ...UPC E Product Reference Guide 6 19 UPC E continued START STATE BARCODE None 2 Digits 5 Digits 2 5 Digits UCC EAN 128 2 Digit UCC EAN 128 5 Digit UCC EAN 128 All END...

Страница 108: ...with EAN 13 bar code data ISBN ISSN When enabled this feature truncates the leading three digits from labels that contain ISBN International Standard Book Number and ISSN International Standard Seria...

Страница 109: ...EAN 13 Product Reference Guide 6 21 EAN 13 continued START STATE BARCODE Disable EAN 13 Enable EAN 13 Don t Send Checksum Send Checksum Disable ISBN ISSN Enable ISBN ISSN END...

Страница 110: ...example we ll set a Code I D of I to repre sent ISBN ISSN The value from the table corresponding to I is 49 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET ISBN CO...

Страница 111: ...13 Product Reference Guide 6 23 EAN 13 continued START STATE BARCODE Set ISBN Code I D Character s DEFAULT SETTING FOR THIS FEATURE I 49 hex Select 0000 to disable Code ID for this symbology only SET...

Страница 112: ...ers to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCA...

Страница 113: ...Code I D of F to represent EAN 13 The hex value from the table corresponding to F is 46 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET EAN 13 CODE I D bar code 4...

Страница 114: ...es 6 26 QuickScan QS6500 QS6500 BT EAN 13 continued START STATE BARCODE Set EAN 13 Code I D Character s DEFAULT SETTING FOR THIS FEATURE F 46 hex Select 0000 to disable Code ID for this symbology only...

Страница 115: ...CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group For e...

Страница 116: ...Symbologies 6 28 QuickScan QS6500 QS6500 BT EAN 13 continued START STATE BARCODE Set EAN 13 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 117: ...ead the main portion of the bar code 2 Digits The imager will read 2 digit add ons with the EAN 13 label 5 Digits The imager will read 5 digit add ons with the EAN 13 label 2 and 5 Digits The imager w...

Страница 118: ...Symbologies 6 30 QuickScan QS6500 QS6500 BT EAN 13 continued START STATE BARCODE None 2 Digits 5 Digits 2 5 Digits UCC EAN 128 2 Digit UCC EAN 128 5 Digit UCC EAN 128 All END...

Страница 119: ...EAN 8 symbology Disable Enable EAN 8 When disabled the imager will not read EAN 8 bar codes Checksum Transmission Enable this option to transmit the checksum along with EAN 8 bar code data START STAT...

Страница 120: ...ing position can be truncated excluded from scanned bar code data Expand EAN 8 to EAN 13 Expands EAN 8 data to the EAN 13 data format Selecting this feature also changes the symbology ID to match thos...

Страница 121: ...o truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCATION...

Страница 122: ...value from the table corresponding to F is 46 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET EAN 8 CODE I D bar code 4 Turn to Appendix B Alpha Numeric Pad and sc...

Страница 123: ...Product Reference Guide 6 35 EAN 8 continued START STATE BARCODE Set EAN 8 Code I D Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Select 0000 to disable Code ID for this symbology only SET...

Страница 124: ...OUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group Fo...

Страница 125: ...EAN 8 Product Reference Guide 6 37 EAN 8 continued START STATE BARCODE Set EAN 8 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 126: ...till read the main portion of the bar code 2 Digits The imager will read 2 digit add ons with the EAN 8 label 5 Digits The imager will read 5 digit add ons with the EAN 8 label 2 and 5 Digits The imag...

Страница 127: ...EAN 8 Product Reference Guide 6 39 EAN 8 continued START STATE BARCODE None 2 Digits 5 Digits 2 5 Digits UCC EAN 128 2 Digit UCC EAN 128 5 Digit UCC EAN 128 All END...

Страница 128: ...GTIN symbology Reference Appendix A ASCII Conversion Chart to find the corresponding hex values for your chosen charac ter s In this example we ll set a Code I D of G to represent GTIN The value from...

Страница 129: ...appear as follows Scanned bar code data 0123456789123 Resulting message string output G0123456789123 GTIN continued START STATE BARCODE Disable GTIN Enable GTIN Set GTIN Code I D Character s DEFAULT S...

Страница 130: ...y Disable Enable RSS 14 When this feature is disabled the imager will not read RSS 14 bar codes Checksum Transmission Enable this option to transmit the checksum along with RSS 14 bar code data UCC EA...

Страница 131: ...RSS 14 Product Reference Guide 6 43 RSS 14 continued START STATE BARCODE Disable RSS 14 Enable RSS 14 Don t Send Checksum Send Checksum Disable UCC EAN 128 Emulation Enable UCC EAN 128 Emulation END...

Страница 132: ...ers to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCA...

Страница 133: ...om the table corresponding to R is 52 and the value for 4 is 34 These values will be used in a step to follow 2 Scan the START bar code 3 Scan the SET RSS 14 CODE I D bar code 4 Turn to Appendix B Alp...

Страница 134: ...6 46 QuickScan QS6500 QS6500 BT RSS 14 continued START STATE BARCODE Set RSS 14 Code I D Character s DEFAULT SETTING FOR THIS FEATURE R4 52hex 34 hex Select 0000 to disable Code ID for this symbology...

Страница 135: ...CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group For e...

Страница 136: ...Symbologies 6 48 QuickScan QS6500 QS6500 BT RSS 14 continued START STATE BARCODE Set RSS 14 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 137: ...RSS Expanded When this feature is disabled the imager will not read RSS Expanded bar codes UCC EAN 128 Emulation When enabled RSS Expanded bar codes will be translated to the UCC EAN 128 label data fo...

Страница 138: ...set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater than the maximum lengt...

Страница 139: ...cters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUN...

Страница 140: ...d The value from the table corresponding to R is 52 and the value for X is 58 These values will be used in a step to follow 2 Scan the START bar code 3 Scan the SET RSS Expanded CODE I D bar code 4 Tu...

Страница 141: ...ct Reference Guide 6 53 RSS Expanded continued START STATE BARCODE Set RSS Expanded Code I D Character s DEFAULT SETTING FOR THIS FEATURE RX 52 hex 58 hex Select 0000 to disable Code ID for this symbo...

Страница 142: ...DATA GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no g...

Страница 143: ...RSS Expanded Product Reference Guide 6 55 RSS Expanded continued START STATE BARCODE Set RSS Expanded Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 144: ...able Enable RSS Limited When this feature is disabled the imager will not read RSS Limited bar codes Checksum Transmission Enable this option to transmit the checksum along with RSS Limited bar code d...

Страница 145: ...ited Product Reference Guide 6 57 RSS Limited continued START STATE BARCODE Disable RSS Limited Enable Limited Don t Send Checksum Send Checksum Disable UCC EAN 128 Emulation Enable UCC EAN 128 Emulat...

Страница 146: ...acters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRU...

Страница 147: ...repre sent RSS Limited The value from the table corresponding to R is 52 and the value for L is 4C These values will be used in a step to follow 2 Scan the START bar code 3 Scan the SET RSS Limited CO...

Страница 148: ...BT Resulting message string output RL0123456789123 RSS Limited continued START STATE BARCODE Set RSS Limited Code I D Character s DEFAULT SETTING FOR THIS FEATURE RL 52hex 4C hex Select 0000 to disabl...

Страница 149: ...A GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no grou...

Страница 150: ...Symbologies 6 62 QuickScan QS6500 QS6500 BT RSS Limited continued START STATE BARCODE Set RSS Limited Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 151: ...When this feature is disabled the imager will not read Code 39 bar codes Checksum Verification When enabled the imager will verify the checksum of the labels Turn this option on only when a checksum i...

Страница 152: ...QuickScan QS6500 QS6500 BT Code 39 continued START STATE BARCODE Disable Code 39 Enable Code 39 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum...

Страница 153: ...um code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater than...

Страница 154: ...ters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNC...

Страница 155: ...the asterisk symbol to represent Code 39 The value from the table corre sponding to is 2A This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET Code 39 CODE I D bar cod...

Страница 156: ...es 6 68 QuickScan QS6500 QS6500 BT Code 39 continued START STATE BARCODE Set Code 39 Code I D Character s DEFAULT SETTING FOR THIS FEATURE 2A hex Select 0000 to disable Code ID for this symbology only...

Страница 157: ...P CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group For...

Страница 158: ...Symbologies 6 70 QuickScan QS6500 QS6500 BT Code 39 continued START STATE BARCODE Set Code 39 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 159: ...ted as a single entry The imager will not transmit the embedded appending code for Code 39 a space If the append function is enabled and other symbols are read again with the appended code then the co...

Страница 160: ...ogies 6 72 QuickScan QS6500 QS6500 BT Code 39 continued START STATE BARCODE Standard Code 39 Full ASCII Code 39 Disable Append Enable Append Disable Start End Transmission Enable Start End Transmissio...

Страница 161: ...re is disabled the imager will not read Pharmacode 39 bar codes Leading A When this option is enabled a letter A is appended to the leading end of Pharmacode 39 bar code data Scanned bar code data 012...

Страница 162: ...m code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater than t...

Страница 163: ...acters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRU...

Страница 164: ...a Code I D of A to repre sent Pharmacode 39 The value from the table corresponding to A is 41 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET PHARMACODE 39 CODE I...

Страница 165: ...roduct Reference Guide 6 77 Pharmacode 39 continued START STATE BARCODE Set Pharmacode 39 Code I D Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex Select 0000 to disable Code ID for this symbolo...

Страница 166: ...DATA GROUP CHARAC TERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no...

Страница 167: ...Pharmacode 39 Product Reference Guide 6 79 Pharmacode 39 continued START STATE BARCODE Set Pharmacode 39 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 168: ...cksum Verification When enabled the imager will verify the checksum of the labels Checksum Transmit Enable this option to transmit the checksum with scanned bar code data Function Code Transmission En...

Страница 169: ...inued START STATE BARCODE Disable Code 128 Enable Code 128 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Transmission Disable Func tion Code...

Страница 170: ...aximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater t...

Страница 171: ...rs to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCAT...

Страница 172: ...I D of the pound sign to represent Code 128 The value from the table corresponding to is 23 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET CODE 128 CODE I D bar...

Страница 173: ...8 Product Reference Guide 6 85 Code 128 continued START STATE BARCODE Set Code 128 Code I D Character s DEFAULT SETTING FOR THIS FEATURE 23 hex Select 0000 to disable Code ID for this symbology only S...

Страница 174: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 175: ...Code 128 Product Reference Guide 6 87 Code 128 continued START STATE BARCODE Set Code 128 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 176: ...will be translated to C1 and any following FNC1 characters will be translated to GS 1Dhex Append When the function is enabled the imager will store but not immediately show data read as long as bar c...

Страница 177: ...Reference Guide 6 89 EAN 128 continued UCC EAN 128 ID setting Specifies UCC EAN 128 label ID 2 bytes to be added to label data START MODE BARCODE UCC EAN 128 ID Setting DEFAULT SETTING FOR THIS FEATU...

Страница 178: ...5 I 2 of 5 symbol ogy Disable Enable Interleaved 2 of 5 When this feature is disabled the imager will not read Interleaved 2 of 5 bar codes Checksum Verification When enabled the imager will verify t...

Страница 179: ...Guide 6 91 Interleaved 2 of 5 continued START STATE BARCODE Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmissi...

Страница 180: ...feature 1 Determine the length settings needed for Fixed Length 1 and Fixed Length 2 then reference Appendix A ASCII Conversion Chart to find the corresponding hex values for your chosen lengths Sele...

Страница 181: ...FAULT SETTINGS FOR THIS FEATURE 00 None Set Fixed Length 1 Scan the bar code above then two digits from Appendix B Alpha Numeric Pad representing the desired length Set Fixed Length 2 Scan the bar cod...

Страница 182: ...imum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater tha...

Страница 183: ...characters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SE...

Страница 184: ...t a Code I D of i to repre sent Interleaved 2 of 5 The value from the table corresponding to i is 69 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET INTERLEAVED 2...

Страница 185: ...Product Reference Guide 6 97 Interleaved 2 of 5 continued START STATE BARCODE Set I 2 of 5 Code I D Character s DEFAULT SETTING FOR THIS FEATURE i 69 hex Select 0000 to disable Code ID for this symbo...

Страница 186: ...OF 5 DATA GROUP CHAR ACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selec...

Страница 187: ...Interleaved 2 of 5 Product Reference Guide 6 99 Interleaved 2 of 5 continued START STATE BARCODE Set Interleaved 2 of 5 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 188: ...The following options apply to the Industrial 2 of 5 I 2 of 5 symbology Disable Enable Industrial 2 of 5 When this feature is disabled the imager will not read Industrial 2 of 5 bar codes START STATE...

Страница 189: ...aximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater t...

Страница 190: ...haracters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET...

Страница 191: ...set a Code I D of i to repre sent Industrial 2 of 5 The value from the table corresponding to i is 69 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET INDUSTRIAL 2...

Страница 192: ...04 QuickScan QS6500 QS6500 BT Industrial 2 of 5 continued START STATE BARCODE Set Code 39 Code I D Character s DEFAULT SETTING FOR THIS FEATURE i 69 hex Select 0000 to disable Code ID for this symbolo...

Страница 193: ...2 OF 5 DATA GROUP CHARAC TERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 sele...

Страница 194: ...Symbologies 6 106 QuickScan QS6500 QS6500 BT Industrial 2 of 5 continued START STATE BARCODE Set Industrial 2 of 5 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 195: ...trix 2 of 5symbology Disable Enable Matrix 2 of 5 When this feature is disabled the imager will not read Matrix 2 of 5 bar codes Checksum Verification When enabled the imager will verify the checksum...

Страница 196: ...S6500 QS6500 BT Matrix 2 of 5 Eur continued START STATE BARCODE Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enab...

Страница 197: ...the maximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not gre...

Страница 198: ...haracters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET...

Страница 199: ...set a Code I D of B to repre sent Matrix 2 of 5 The value from the table corresponding to B is 42 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET MATRIX 2 OF 5 COD...

Страница 200: ...QuickScan QS6500 QS6500 BT Matrix 2 of 5 Eur continued START STATE BARCODE Set Matrix 2 of 5 Code I D Character s DEFAULT SETTING FOR THIS FEATURE B 42 hex Select 0000 to disable Code ID for this symb...

Страница 201: ...OF 5 DATA GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects...

Страница 202: ...Symbologies 6 114 QuickScan QS6500 QS6500 BT Matrix 2 of 5 Eur continued START STATE BARCODE Set Matrix 2 of 5 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 203: ...abar symbology Disable Enable Codabar When this feature is disabled the imager will not read Codabar bar codes Checksum Verification When enabled the imager will verify the checksum of the labels Chec...

Страница 204: ...QuickScan QS6500 QS6500 BT Codabar continued START STATE BARCODE Disable Codabar Enable Codabar Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum...

Страница 205: ...um code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater than...

Страница 206: ...ters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNC...

Страница 207: ...of the percent sign to represent Codabar The value from the table correspond ing to is 25 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET CODABAR CODE I D bar code...

Страница 208: ...es 6 120 QuickScan QS6500 QS6500 BT Codabar continued START STATE BARCODE Set Codabar Code I D Character s DEFAULT SETTING FOR THIS FEATURE 25 hex Select 0000 to disable Code ID for this symbology onl...

Страница 209: ...UP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group For...

Страница 210: ...Symbologies 6 122 QuickScan QS6500 QS6500 BT Codabar continued START STATE BARCODE Set Codabar Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 211: ...to match your application Start End Transmission The transmission of start and end characters of Codabar is selected below START STATE BARCODE Start Stop Type ABCD ABCD Start Stop Type abcd abcd Star...

Страница 212: ...Code 93 symbology Disable Enable Code 93 When this feature is disabled the imager will not read Code 93 bar codes Checksum Verification When enabled the imager will verify the checksum of the labels C...

Страница 213: ...t Reference Guide 6 125 Code 93 continued START STATE BARCODE Disable Code 93 Enable Code 93 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Tr...

Страница 214: ...ximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater th...

Страница 215: ...s to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCATI...

Страница 216: ...a Code I D of to represent Code 93 The value from the table corresponding to is 26 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET CODE 93 CODE I D bar code 4 Tur...

Страница 217: ...roduct Reference Guide 6 129 Code 93 continued START STATE BARCODE Set Matrix 2 of 5 Code I D Character s DEFAULT SETTING FOR THIS FEATURE 26 hex Select 0000 to disable Code ID for this symbology only...

Страница 218: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 219: ...Code 93 Product Reference Guide 6 131 Code 93 continued START STATE BARCODE Set Code 93 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 220: ...ode 11 When this feature is disabled the imager will not read Code 11 bar codes Checksum Verification When enabled the imager will verify the check sum of the labels Checksum Transmit When this option...

Страница 221: ...e 6 133 Code 11 continued START STATE BARCODE Disable Code 11 Enable Code 11 Disable Checksum Verification 1 Digit Checksum Verification 2 Digit Checksum Verification Disable Checksum Transmission Ena...

Страница 222: ...ximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater th...

Страница 223: ...s to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCATI...

Страница 224: ...Code I D of O to represent Code 11 The value from the table corresponding to O is 4F This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET CODE 11 CODE I D bar code 4 Tu...

Страница 225: ...oduct Reference Guide 6 137 Code 11 continued START STATE BARCODE Set Matrix 2 of 5 Code I D Character s DEFAULT SETTING FOR THIS FEATURE O 4F hex Select 0000 to disable Code ID for this symbology onl...

Страница 226: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 227: ...Code 11 Product Reference Guide 6 139 Code 11 continued START STATE BARCODE Set Code 11 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 228: ...ill not read MSI Plessey bar codes Checksum Verification The imager will verify Mod 10 Mod 10 10 Mod 11 10 or no check digits Turn checksum verification on only when one or more checksums are present...

Страница 229: ...continued START STATE BARCODE Disable MSI Plessey Enable MSI Plessey Disable Checksum Verification Mod 10 Checksum Verification Mod 10 10 Checksum Verification Mod 11 10 Checksum Verification Disable...

Страница 230: ...maximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater...

Страница 231: ...cters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUN...

Страница 232: ...et a Code I D of to repre sent MSI Plessey The value from the table corresponding to is 40 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET MSI PLESSEY CODE I D bar...

Страница 233: ...Product Reference Guide 6 145 MSI Plessey continued START STATE BARCODE Set MSI Plessey Code I D Character s DEFAULT SETTING FOR THIS FEATURE 40 hex Select 0000 to disable Code ID for this symbology o...

Страница 234: ...ATA GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no gr...

Страница 235: ...MSI Plessey Product Reference Guide 6 147 MSI Plessey continued START STATE BARCODE Set MSI Plessey Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 236: ...K Plessey symbology Disable Enable UK Plessey When this feature is disabled the imager will not read UK Plessey bar codes Checksum Verification When enabled the imager will verify the check sum of the...

Страница 237: ...eference Guide 6 149 UK Plessey continued START STATE BARCODE Disable UK Plessey Enable UK Plessey Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Check...

Страница 238: ...maximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater...

Страница 239: ...ters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNC...

Страница 240: ...et a Code I D of to represent UK Plessey The value from the table corresponding to is 40 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET UK PLESSEY CODE I D bar co...

Страница 241: ...Product Reference Guide 6 153 UK Plessey continued START STATE BARCODE Set MSI Plessey Code I D Character s DEFAULT SETTING FOR THIS FEATURE 40 hex Select 0000 to disable Code ID for this symbology on...

Страница 242: ...ATA GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no gr...

Страница 243: ...UK Plessey Product Reference Guide 6 155 UK Plessey continued START STATE BARCODE Set UK Plessey Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 244: ...epen When this feature is disabled the imager will not read Telepen bar codes Checksum Verification When enabled the imager will verify the check sum of the labels Checksum Transmit When this option i...

Страница 245: ...157 Telepen continued START STATE BARCODE Disable Telepen Enable Telepen Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Transmission Format N...

Страница 246: ...ximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater th...

Страница 247: ...s to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCATI...

Страница 248: ...Code I D of S to represent Telepen The value from the table corresponding to S is 53 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET TELEPEN CODE I D bar code 4 Tu...

Страница 249: ...Product Reference Guide 6 161 Telepen continued START STATE BARCODE Set Telepen Code I D Character s DEFAULT SETTING FOR THIS FEATURE S 53 hex Select 0000 to disable Code ID for this symbology only S...

Страница 250: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 251: ...Telepen Product Reference Guide 6 163 Telepen continued START STATE BARCODE Set Telepen Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 252: ...ard 2 of 5 symbology Disable Enable Standard 2 of 5 When this feature is disabled the imager will not read Standard 2 of 5 bar codes Checksum Verification When enabled the imager will verify the check...

Страница 253: ...eference Guide 6 165 Standard 2 of 5 continued START STATE BARCODE Disable Std 2 of 5 Enable Std 2 of 5 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable...

Страница 254: ...e maximum code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greate...

Страница 255: ...haracters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET...

Страница 256: ...a Code I D of S to repre sent Standard 2 of 5 The value from the table corresponding to S is 53 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET STANDARD 2 OF 5 CO...

Страница 257: ...Product Reference Guide 6 169 Standard 2 of 5 continued START STATE BARCODE Set Std 2 of 5 Code I D Character s DEFAULT SETTING FOR THIS FEATURE S 53 hex Select 0000 to disable Code ID for this symbol...

Страница 258: ...5 DATA GROUP CHARAC TERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects...

Страница 259: ...Standard 2 of 5 Product Reference Guide 6 171 Standard 2 of 5 continued START STATE BARCODE Set Standard 2 of 5 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 260: ...500 QS6500 BT Code 16K The following options apply to the Code 16K symbology Disable Enable Code 16K When this feature is disabled the imager will not read Code 16K bar codes START STATE BARCODE Disab...

Страница 261: ...rs to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNCAT...

Страница 262: ...Code I D of C to represent Code 16K The value from the table corresponding to C is 43 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET Code 16K CODE I D bar code 4...

Страница 263: ...16K Product Reference Guide 6 175 Code 16K continued START STATE BARCODE Set Code 16K Code I D Character s NO DEFAULT SETTING FOR THIS FEATURE Select 0000 to disable Code ID for this symbology only SE...

Страница 264: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 265: ...Code 16K Product Reference Guide 6 177 Code 16K continued START STATE BARCODE Set Code 16K Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 266: ...6500 BT China Post The following options apply to the China Post symbology Disable Enable China Post When this feature is disabled the imager will not read China Post bar codes START STATE BARCODE Dis...

Страница 267: ...code length is set to zero the global maximum is in effect If the minimum code length is set to zero the global minimum is in effect NOTE Ensure that the minimum length setting is not greater than the...

Страница 268: ...acters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRU...

Страница 269: ...ode I D of t to represent China Post The value from the table corresponding to t is 74 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET CHINA POST CODE I D bar code...

Страница 270: ...6 182 QuickScan QS6500 QS6500 BT China Post continued START STATE BARCODE Set China Post Code I D Character s DEFAULT SETTING FOR THIS FEATURE NONE Select 0000 to disable Code ID for this symbology o...

Страница 271: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 272: ...Symbologies 6 184 QuickScan QS6500 QS6500 BT China Post continued START STATE BARCODE Set China Post Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 273: ...gy Disable Enable PDF 417 When this feature is disabled the imager will not read PDF 417 bar codes Escape Sequence Transmit Disables enables transmission of the escape sequence START STATE BARCODE Dis...

Страница 274: ...ters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TRUNC...

Страница 275: ...I D of P to represent PDF 417 The value from the table corresponding to P is 50 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET Code PDF 417 I D bar code 4 Turn t...

Страница 276: ...s 6 188 QuickScan QS6500 QS6500 BT PDF 417 continued START STATE BARCODE Set PDF 417 Code I D Character s DEFAULT SETTING FOR THIS FEATURE S 53 hex Select 0000 to disable Code ID for this symbology on...

Страница 277: ...UP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group For...

Страница 278: ...Symbologies 6 190 QuickScan QS6500 QS6500 BT PDF 417 continued START STATE BARCODE Set PDF 417 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 279: ...e Micro PDF 417 When this feature is disabled the imager will not read Micro PDF 417 bar codes Escape Sequence Transmit Specifies transmission format of the escape sequence START STATE BARCODE Disable...

Страница 280: ...racters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET TR...

Страница 281: ...t a Code I D of U to repre sent Micro PDF 417 The value from the table corresponding to U is 55 This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET MICRO PDF 417 I D b...

Страница 282: ...4 QuickScan QS6500 QS6500 BT Micro PDF 417 continued START STATE BARCODE Set Micro PDF 417 Code I D Character s DEFAULT SETTING FOR THIS FEATURE U 55 hex Select 0000 to disable Code ID for this symbol...

Страница 283: ...DATA GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no g...

Страница 284: ...Symbologies 6 196 QuickScan QS6500 QS6500 BT Micro PDF 417 continued START STATE BARCODE Set Micro PDF 417 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 285: ...CC Composite When this feature is disabled the imager will not read EAN UCC Com posite bar codes UCC EAN 128 Emulation When enabled EAN UCC Composite bar codes will be translated to the UCC EAN 128 la...

Страница 286: ...haracters to truncate from either the leading or ending charac ters of scanned bar code data To configure this feature scan the START bar code above to place the unit in Programming Mode then the SET...

Страница 287: ...ent EAN UCC Composite The value from the table corresponding to R is 52 for C 43 These value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET EAN UCC COMPOSITE I D bar code 4...

Страница 288: ...kScan QS6500 QS6500 BT EAN UCC Composite continued START STATE BARCODE Set EAN UCC Composite Code I D Character s DEFAULT SETTING FOR THIS FEATURE RC 5243 hex Select 0000 to disable Code ID for this s...

Страница 289: ...MPOSITEDATA GROUP CHAR ACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 sele...

Страница 290: ...Symbologies 6 202 QuickScan QS6500 QS6500 BT EAN UCC Composite continued START STATE BARCODE Set EAN UCC Composite Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 291: ...es Disable Enable Code 4 and Code 5 When this feature is disabled the imager will not read Code 4 or Code 5 bar codes Data Transmission Format Hex or decimal data transmission format may be selected S...

Страница 292: ...D of N to represent Code 4 5 The value from the table corresponding to N is 4E This value will be used in a step to follow 2 Scan the START bar code 3 Scan the SET Code 4 5 I D bar code 4 Turn to Appe...

Страница 293: ...Product Reference Guide 6 205 Code 4 5 continued START STATE BARCODE Set Code 4 5 Code I D Character s DEFAULT SETTING FOR THIS FEATURE N 4E hex Select 0000 to disable Code ID for this symbology only...

Страница 294: ...GROUP CHARACTERS bar code 4 Turn to Appendix B Alpha Numeric Pad and scan the digits repre senting the Data Group designation s chosen in the first step above A digit of value zero 0 selects no group...

Страница 295: ...Code 4 5 Product Reference Guide 6 207 Code 4 5 continued START STATE BARCODE Set Code 4 5 Data Group s DEFAULT SETTING FOR THIS FEATURE None 00 SET END...

Страница 296: ...Symbologies 6 208 QuickScan QS6500 QS6500 BT NOTES...

Страница 297: ...iguration This is accomplished by the linked imager and Base Station comparing application version number and configuration file check sum If either is different the Base Sta tion will automatically u...

Страница 298: ...Bluetooth Features 7 2 QuickScan QS6500 QS6500BT Auto Update continued START STATE BARCODE Auto Update Enable Configure Auto Update Enable Application Auto Update Enable Auto Update Disable END...

Страница 299: ...an be placed into Deep Sleep Mode after this programmed duration since the unit s last scanning activity Press its trigger to wake the imager from this mode START DURATION BARCODE Disable 20 Minutes 3...

Страница 300: ...This is especially useful in instances where the imager might inadvertently have been placed in a bag or cart For this mode to be effective Deep Sleep Mode must be disabled If the imager is asleep th...

Страница 301: ...Leash Alarm Product Reference Guide 7 5 9 Seconds 10 Seconds 15 Seconds 20 Seconds 25 Seconds 30 Seconds 35 Seconds 40 Seconds 45 Seconds 50 Seconds 55 Seconds 60 Seconds END START DURATION BARCODE...

Страница 302: ...D bar code to exit Programming Mode 4 Scan the Begin Pin bar code 5 Set the four to six character PIN code assigned to the target Blue tooth device using the bar codes available in Appendix B Alpha Nu...

Страница 303: ...Bluetooth Connectivity Mode Product Reference Guide 7 7 Bluetooth Connectivity Mode continued START STATE BARCODE Connect to Base Station Connect to a BT Device END Begin Pin End Pin...

Страница 304: ...p can be disabled or reconfigured to sound for different durations by using the following pro gramming bar codes START STATE BARCODE Disable Inquiry Beep Inquiry Beep 10 Seconds Inquiry Beep 20 Second...

Страница 305: ...Inquiry Beep Control Product Reference Guide 7 9 Inquiry Beep 5 Minutes Inquiry Beep 6 Minutes Inquiry Beep 7 Minutes Inquiry Beep 8 Minutes END START STATE BARCODE...

Страница 306: ...Bluetooth Features 7 10 QuickScan QS6500 QS6500BT NOTES...

Страница 307: ...5 to 14 VDC 5 Input Power Operating Standby 1250 mW POT w all interfaces 500 mW Input Current Operating Standby 300mA 5VDC 200mA 5VDC Skew 55q Pitch 65q Temperature Ranges Operating 32q F to 122q F 0q...

Страница 308: ...ary Interface Cables RS 232 Keyboard Wedge 1 2 CTS 3 4 RTS 5 RXD 6 TXD 7 8 VCC_IN 9 GND 10 Pin 10 Pin 1 10 Pin Modular Plug Connects to the imager module 1 2 KBDATA 3 PCCLK 4 KBCLK 5 NC 6 PCDATA 7 NC...

Страница 309: ...rence Guide 8 3 USB IBM Port 5B 9B 17 Pin 10 Pin 1 10 Pin Modular Plug Connects to the imager module 1 2 3 4 D 5 6 D 7 8 VBUS_VIN 9 GND 10 Pin 10 Pin 1 10 Pin Modular Plug Connects to the imager modul...

Страница 310: ...Product Specifications 8 4 QuickScan QS6500 QS6500 BT NOTES...

Страница 311: ...B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J...

Страница 312: ...A 2 QuickScan QS6500 QS6500BT...

Страница 313: ...roduct Reference Guide B 1 Appendix B Alpha Numeric Pad Use the bar codes contained in this chapter to modify configuration set tings as described in the feature option descriptions 0 5 1 6 2 7 3 8 4...

Страница 314: ...B 2 QuickScan QS6500 QS6500BT A D B E C F...

Страница 315: ...Modifier Scancode 00 NUL ALT right Make 40h 00h 01 SOH ALT right Break 00h 00h1 02 STX F11 00h 44h 03 ETX F12 00h 45h 04 EOT GUI right Make 80h 00h 05 ENQ GUI right Break 00h 00h1 06 ACK CTRL right M...

Страница 316: ...col Scancode Set Func Key Map Support Use Country Mode PC XT Foreign ALT Mode Wedge A PC XT Scan Set 1 No No AT PS 2 25 286 PS 2 30 286 PS 2 50 50Z PS 2 60 70 80 90 95 Foreign ALT Mode Wedge B AT PS2...

Страница 317: ...k E0h B8h 02 STX ALT left Make 38h 03 ETX ALT left Break B8h 04 EOT CTRL left Make 1Dh 05 ENQ CTRL left Break 9Dh 06 ACK CTRL right Make E0h 1Dh 07 BEL CTRL right Break E0h 9Dh 08 BS BS 0Eh 09 HT TAB...

Страница 318: ...14h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 74h E0 0B VT TAB left 0Dh S 0C FF Enter right keypad 5Ah E0 0D CR CR 5Ah 0E SO INSERT inner keypad 70h E0 0F SI PAGE UP inner keypa...

Страница 319: ...BEL CTRL right Break F0h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF Enter inner keypad 79h 0D CR CR 5Ah 0E SO INSERT inner keypad 67h 0F SI PAGE...

Страница 320: ...NLINE Enter Make Break 58h F0h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF CR FIELD EXIT Make only 5Ah F0h 5Ah 0D CR CR FIELD EXIT Make Break 5Ah...

Страница 321: ...Break C1h 08h BS BS 3Eh 09h HT TAB right 3Ch 0Ah LF RIGHT arrow inner keypad 4Dh 0Bh VT TAB left 3Ch S 0Ch FF Enter right keypad 60h 0Dh CR CR 3Bh 0Eh SO INSERT inner keypad 52h 0Fh SI PAGE UP inner...

Страница 322: ...9h HT TAB right 0Fh 0Ah LF RIGHT arrow inner keypad 3Ch 0Bh VT TAB left 0Fh S 0Ch FF DELETE 39h 0Dh CR CR 1Ch 0Eh SO INSERT inner keypad 38h 0Fh SI KATAKANA LOCK ON Make 72h 10h DLE KATAKANA LOCK OFF...

Страница 323: ...h symbology type Code Type Read Enable Checksum Verification Enable Checksum Transmission Enable Code ID UPC A A UPC E E EAN 13 F EAN 8 FF RSS 14 R4 RSS Expanded RX RSS Limited RL Code 39 PharmaCode 3...

Страница 324: ...rface for the remaining available interfaces IBM Interfaces IBM Interfaces include IBM USB IBM Port 9B IBM Port5B and IBM Port17 UK Plessey Telepen S Standard 2 of 5 S Code 16K China Post PDF417 P Mic...

Страница 325: ...AN 128 Code I D P Code 39 Read Disable Code 39 Code I D M Code 93 Code I D L Code 128 Read Disable Code 128 Code I D K Codabar Code I D N EAN 8 Code I D B EAN 13 Code I D A ISBN Code I D A Interleaved...

Страница 326: ...Keyboard and Keyboard Wedge A J Wand Emulation Parameter Default Setting Keyboard Wedge Interface Type USB Keyboard Code I D Transmission Disable Parameter Default Setting Code I D Transmission Disabl...

Страница 327: ...your scanner List Unique Parameter Settings Displays any unique parame ter settings currently pro grammed into your scanner List String Settings Displays any data string set tings currently programme...

Страница 328: ...E 2 QuickScan QS6500 QS6500 BT NOTES...

Страница 329: ...Bluetooth Imager Indications STATUS GREEN LED RED LED ORANGE LED BEEPER Connected or re enter into the boundary When scanner is sleeping Blink once Special beep Disconnected or Out of boundary When s...

Страница 330: ...LED Beeper Indications F 2 QuickScan QS6500 QS6500 BT Data transmission OK ON for Xmsec Low battery Trigger is pressed only Blinks STATUS GREEN LED RED LED ORANGE LED BEEPER...

Страница 331: ...c ond BlueTooth Status LED Connecting Link estab lished ON Hardware fail Flash Data receiving from the scan ner On for 0 5 second Bar code data proof or trans mitted Good beep for test only Data send...

Страница 332: ...LED Beeper Indications F 4 QuickScan QS6500 QS6500 BT NOTES...

Страница 333: ...erence Guide G 1 Appendix G Sample Symbols 0 123456 7890 1234567890 Code 128 9 780330 290951 BC321 123456 9 123456 UPC A Code 128 Code 39 Code 93 Interleaved 2 of 5 EAN 13 Industrial Code 2 of 5 A1357...

Страница 334: ...G 2 QuickScan QS6500 QS6500 BT Sample Symbols continued 6543210 01 00123456789012 Matrix 2 of 5 RSS 14 Sample Symbols for PDF Models ONLY Micro PDF417 Test Message PDF417 Car Registration...

Страница 335: ......

Страница 336: ...39 6859496 Japan Datalogic Scanning KK Shinagawa Tokyo Japan Telephone 81 0 3 3491 6761 Fax 81 0 3 3491 6656 Latin America Datalogic Scanning Inc Miami Florida USA Telephone 305 591 3222 Fax 305 591 3...

Отзывы: