User guide GENIO 10
Page 7
Optional Remote Control
for outputs1 and 2
By inserting the two prints you have the possibility to regulate the outputs from far away. For this purpose the
jumpers 11 and 12 must be unsoldered.
If you want
the microphones 1-8 to work independently of the automatic
switch the two jumpers on the
desired microphones to the input and output
.
3. Operation oft he device
3.1 Microprocessor-Gate-Control
Continuous monitoring of 5 input channels by RISC microprocessor.
Level comparing accuracy better than ± 2dB
Channel activation time less than 10 ms
Channel activation hold time of 256 ms (default) / 512 ms, switch selectable
Last ON (default) /Channel 1 On, switch selectable, hysteresis 6 dB
Simultaneously activated channels: one, two, three or four.
Switch 1
Hold-Time
Off
256 ms
On
512 ms
Switch 2
Activated channel
Off
Last channel
On
Channel 1
Switch 3
Switch 4
Simultaneously activated channels
Off
Off
1 (input 1 - 8)
Off
On
2 (input 1 - 8)
On
Off
3 (input 1 - 8)
On
On
4 (input 1 - 8)