4.2.3  Config

 

With Config you have the possibility to decide with which preset and parameterset the program will start when 
turned  on.  F

urther  adjustments  will  be  described  below.  By  pressing  the  “preset”  dial  you  will  enter  to  the 

Config-

menu, when the little triangle is next to “Config”. (See below) 

 

 
 
 
 
 
 
 

  Now you can see the startup-preset starting the program on the display. By turning the 

“volume” dial you can 

 

  change with which preset the program should start with (1-

20). By turning the “preset” dial you will enter to the 

 

  startup parameter menu. Here you can select with which parameters the program should start (1-4). 

VU Out

: By turning the volume dial, you can choose which of the two outputs shall be shown as VU-meters on 

the display. 

LCD contrast

: Set the contrast oft he LCD display from 0 to 50 for optimal readability. 

Vol/Preset  Protect

:  The  protection  of  the  settings  is  such  that  changes  (e.g.  changing  between  presets  or 

temporary volume changes) can only be performed while pushing und turning the dials at the same changes 
can  be  made  by  simply  turning  the  dials  without  pushing  them.  Turning  the  volume  dial  by  one  click  either 
enable or disables the protection. 

Welcomescreen Line 1

: Set the first line (16 characters) oft he welcome text that shows up when powering 

up  the  unit.  The  cursor  will  blink  under  the  first  character.  By  turning  the  volume  dial,  the  following  letters  , 
numbers and special characters will appear in this order: A-Z, Ä, Ö, Ü, a-z, ä, ö, ü, 0-9, space, 

! „ # $ % & ’ ( ) 

*  +  ,  -  .  /  Pushing  the  preset dial  will  confirm  the  current  character  and  move  the  cursor  one  position  to  the 
right. Now you can see the next character. 

Welcomescreen  Line  2

:  Set  the  second  line  (16  characters)  of  the  welcome  text  that  shows  up  when 

powering up the unit. 

Output 1 Name

: Determine the name of the first output. 8 characters are available for this name (e.g. nave, 

gallery etc.) 

 

  Output 2 Name

: Same procedure as in Output Name 1. 

4.2.4  Utility 

      Inside this menu you have the possibility to copy a parameterset into another parameterset. 
     

Turn the “volume” dial until the small triangle in next to “Utility” and press the “preset” dial.  

 

    Now you can see 

“Copy/Firmware” on the display. By pressing the dial again the following menu    

will 

    appear (see below) 

 

 
 
 
 
 
 

By turning the „volume“ dial the source and target parameter set for the copy process can be determined. 
When th

e triangle is on “Copy”, press the “preset” dial. Now the designed parameter set is copied. 

 

 

  Firmware

: Displays the current firmware version of the unit. 

 

 

 
 

 
 
 
 

Содержание GENIO 10

Страница 1: ...User guide GENIO 10 Issue 10 2016 Vertriebs Entwicklungsgesellschaft mbH Genio 10 Automatic Mix Amplifier User guide...

Страница 2: ...Microprocessor Gate control 7 3 2 Programmable settings Presets 8 3 3 Use of different settings Presets 8 3 4 Change of existing preset settings 8 4 Advanced features 4 1 Creating new presets 9 4 2 Th...

Страница 3: ...sensitivity for Aux Output 1 and Output 2 for controlling an external power amp The speaker outputs are designed for 100 70 50 V and also for 4 ohm Each output has a 31 band graphic equalizer a 6 para...

Страница 4: ...At one end of this cable is a three pronged AC power connector IEC plug and at the other end a CE standard compliant Schuko plug for connecting to a 230V 50 Hz AC voltage source Please ensure that th...

Страница 5: ...lume control channels 1 8 With the volume controls the level of the signal sources can be adjusted which are connected to the microphone line inputs During the installation by the technical staff the...

Страница 6: ...D audio RCA connections for music transfer via CD with selectable sensitivity 7 Playback RCA connections for music transfer Aux with selectable sensitivity and volume control 8 Remote Control Print Op...

Страница 7: ...1 Microprocessor Gate Control Continuous monitoring of 5 input channels by RISC microprocessor Level comparing accuracy better than 2dB Channel activation time less than 10 ms Channel activation hold...

Страница 8: ...how up Below an example is given Here one can see the current preset name in this case Sonntag as well as the value of the master volume in percent total output volume in this case 80 The bar above th...

Страница 9: ...eset dial will confirm the current character and move the cursor one position to the right Now you can set the next character When you ve filled the preset name turn the preset dial one click to the r...

Страница 10: ...lowing applies Turning preset dial one click to he right will always bring you to the next item of a menu i e to the next parameter to be programmed This dial is therefore marked parameter For simplic...

Страница 11: ...level Param EQ 1 Freq Set the 1 st frequency of the full parametric equalizers range 20 Hz to 20 45 kHz Here too the value is set with the volume dial Pushing the preset dial will bring you to the ne...

Страница 12: ...by one click either enable or disables the protection Welcomescreen Line 1 Set the first line 16 characters oft he welcome text that shows up when powering up the unit The cursor will blink under the...

Страница 13: ...adjustable for each output Param EQ 1 Q Q factor of the 1st parametric equalizer adjustable for each output same for the other parametric equalizers Limiter on off Set limiter individually for each ou...

Страница 14: ...ut sensitivity DIP switch ON 14 dBu 2 dBu CD Input sensitivity DIP switch OFF 4 dBu CD Input sensitivity DIP switch ON 6 dBu CD AUX frequency response 20 Hz 20 kHz CD AUX USB Equalizer Low 12 dB 100 H...

Страница 15: ...es of use of such information or for any infringement of patents or other rights of third parties that may result from its use No license is granted by implication or otherwise under any patent or pat...