![Avaya G600 Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/avaya/g600/g600_installing-manual_3027010131.webp)
131
Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Connect the MDF to Stations and PSTN
May 2003
3-Pair to 4-Pair Circuit Distribution and Connectivity
Connected cable station adapters
Station adapters are used to provide modular connectivity either directly to a telephone or to an
information outlet.
Figure notes
1
Part of Main Distribution Frame
(MDF)
2
3-Pair Connecting Blocks
3
Purple Field
4
Blue Field
5
Patch Cord or Cross-Connect
Jumpers
6
To Media Gateway (3-Pair
Modularity)
7
B25A Cable
8
3-Pair Circuits
9
356A Adapter
10
Information Outlet
11
3-Pair Circuit in 4-Pair Wire
12
DIW Station Cable (D-Inside Wire)
8
7
1
9
10
11
12
r758533a CJL 031196
2
2
4
3
6
5
Содержание G600
Страница 1: ...Installing the Avaya S8700 Media Server with an Avaya G600 Media Gateway Release 1 3 Issue 3 May 2003 ...
Страница 20: ...20 DocumentTitle Variable Download License and Avaya Authentication Files May 2003 ...
Страница 273: ...273 Installing the Avaya S8700 Media Server with Avaya G600 Media Gateway Index May 2003 Z ZD8AJ adapter 125 ...
Страница 274: ...274 Installing the Avaya S8700 Media Server with Avaya G600 Media Gateway Index May 2003 ...