Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Connect the Media Gateway to the MDF
May 2003
Trunk Cables Among Network Interface,
Sneak Fuse Panel, and Media Gateway
The 1-pair of Central Office (CO) trunks are installed by the network provider in the green field.
Up to 24 pairs may be terminated on each row of the 110-type terminal block. Tie trunks also
appear in the green field with up to eight 3-pair trunks terminated on each row of the 110-type
terminal block.
WP-90929, List 1 and 3 concentrator cables can be used to connect the media gateway to the
110-type terminal blocks in the purple field. The 1-pair patch cords/jumper wires are then run
from the purple terminal block rows to the green terminal block rows in order to establish the
correct 3-pair modularity.
Equipment Room Cabling Labels
Figure notes
1
Purple Label (Port Cable)
2
Blue/Yellow Label (Building
and Floor)
3
Yellow Label (Auxiliary)
4
Blue/Yellow Label (Site or
Satellite)
Equipment Room Labels
Label Name
Range
Port Cable
1A1-1A20, 1B1-1B20, 1C1-1C20,
1D1-1D20, 1E1-1E20
Building
Field Identified
Floor
Field Identified
Auxiliary Cable
Field Identified
Site or Satellite
A-F and/or Field Identified
labels LJK 060396
1 A 2
A
Содержание G600
Страница 1: ...Installing the Avaya S8700 Media Server with an Avaya G600 Media Gateway Release 1 3 Issue 3 May 2003 ...
Страница 20: ...20 DocumentTitle Variable Download License and Avaya Authentication Files May 2003 ...
Страница 273: ...273 Installing the Avaya S8700 Media Server with Avaya G600 Media Gateway Index May 2003 Z ZD8AJ adapter 125 ...
Страница 274: ...274 Installing the Avaya S8700 Media Server with Avaya G600 Media Gateway Index May 2003 ...